Related Experiment Video
Updated: May 4, 2026

Rejection of Fluorescence Background in Resonance and Spontaneous Raman Microspectroscopy
Published on: May 18, 2011
Monitoring of chemotherapy leukemia treatment using Raman spectroscopy and principal component analysis
José Luis González-Solís1, Juan Carlos Martínez-Espinosa, Juan Manuel Salgado-Román
1Biophysics and Biomedical Sciences Laboratory, Centro Universitario de los Lagos, Universidad de Guadalajara, Enrique Díaz de León 1144, Paseo de la Montaña, CP 47460, Lagos de Moreno, Jalisco, México, jluis0968@gmail.com.
Abstract:
In this research, we used the Raman spectroscopy to distinguish between normal and leukemia blood serum and identify the different types of leukemia based on serum biochemistry. In addition, monitoring of patients under chemotherapy leukemia treatment (CHLT) was studied. Blood samples were obtained from seven patients who were clinically diagnosed with three leukemia types and 21 healthy volunteers. In addition, other five leukemia patients were monitored during the CHLT, two patients were declared healthy, one patient suspended it; the health of the other two patients worsened, and no improvement was observed along CHLT. The serum samples were put under an Olympus microscope integrated to the Raman system, and several points were chosen for the Raman measurement. The Horiba Jobin Yvon LabRAM HR800 Raman system is equipped with a liquid nitrogen-cooled detector and a laser of 830 nm with a power irradiation of 17 mW. It is shown that the serum samples from patient with leukemia and from the control group can be discriminated when multivariate statistical methods of principal component analysis (PCA) and linear discriminant analysis (LDA) are applied to their Raman spectra obtaining two large clusters corresponding to the control and leukemia serum samples and three clusters inside the leukemia group associated with the three leukemia types. The major differences between leukemia and control spectra were at 1,338 (Trp, α-helix, phospholipids), 1,447 (lipids), 1,523 (β-carotene), 1,556 (Trp), 1,587 (protein, Tyr), 1,603 (Tyr, Phe), and 1,654 (proteins, amide I, α-helix, phospholipids) cm(-1), where these peaks were less intense in the leukemia spectrum. Minor differences occurred at 661 (glutathione), 890 (glutathione), 973 (glucosamine), 1,126 (protein, phospholipid C-C str), 1,160 (β-carotene), 1,174 (Trp, Phe), 1,208 (Trp), 1,246 (amide III), 1,380 (glucosamine), and 1,404 (glutathione) cm(-1). Leukemia spectrum showed a peak at 917 cm(-1) associated with glutathione, but it was absent in the control spectrum. The results suggest that the Raman spectroscopy and PCA could be a technique with a strong potential of support for current techniques to detect and identify the different leukemia types by using a serum sample. Nevertheless, with the construction of a data library integrated with a large number of leukemia and control Raman spectra obtained from a wide range of healthy and leukemic population, the Raman-PCA technique could be converted into a new technique for minimally invasive real-time diagnosis of leukemia from serum samples. In addition, complementary results suggest that using these techniques is possible to monitor CHLT.
More Related Videos
Related Concept Videos
Raman Spectroscopy: Overview
However, a small fraction of the scattered light exhibits a frequency shift due to the exchange of energy between the incident photons and...
Raman Spectroscopy Instrumentation: Overview
The monochromatic laser source, typically using visible or near-infrared radiation, generates a highly focused beam of light. This light interacts with the molecules of the sample, scattering some of the light. Liquid and gaseous samples are usually tested in ordinary glass capillaries, while solids can be analyzed as powders packed in capillaries or as potassium...

