Design and analysis considerations for thorough QT studies employing conventional (10 s, 12-lead) ECG recordings
Charles M Beasley1, Alex Dmitrienko, Malcolm I Mitchell
1Lilly Corporate Center, Indianapolis, IN 46285, USA. cmbeasleyj@lilly.com.
Abstract:
The QT interval from the ECG cannot be measured precisely. The relationship of the QT interval to the RR interval within individuals across time and different RR values, and across individuals eludes complete understanding. Intrinsic beat-to-beat variability in QT interval corrected for heart rate (QTc interval) is not trivial. Therefore, it is difficult to determine a valid and reliable estimate of the time for ventricular repolarization based on the QTc interval. Yet, it must be demonstrated that a drug does not result in an increase in the QTc interval that exceeds 5 ms with some reasonable degree of certainty to be quite confident that the drug does not convey some risk of ventricular tachydysrhythmia due to delayed ventricular repolarization. This demonstration can be a Herculean task due to the magnitude of variability in the QTc interval. Design features and analytical methods that might be used in the thorough QT study to improve the chances of demonstrating the true relationship between a drug and QTc interval are reviewed.
Related Concept Videos
Electrocardiogram
Three major waveforms are present in a typical ECG recording: the P wave, the QRS complex, and...
Electrocardiogram Fundamentals
An electrocardiogram (ECG) is a diagnostic tool for identifying cardiac conditions such as arrhythmias, conduction abnormalities, and myocardial ischemia.
Definition
An electrocardiogram (ECG) visualizes the heart's electrical activity by tracing the electrical movement associated with each heartbeat on a graph or monitor. As the heart beats, an electrical wave passes through it, correlating with the cardiac cycle events.
Parts of an ECG
An ECG utilizes electrodes on the skin...
ECG Interpretation of Rhythms
Components of the Electrocardiogram
The primary components of a normal ECG waveform in Normal sinus rhythm(NSR) include the P wave, PR interval, QRS complex, ST segment, T wave, and occasionally a U wave.
ECG waveforms are divided by vertical and horizontal lines at standard intervals.
The horizontal axis measures time and rate, and the vertical axis measures amplitude or voltage....
Dysrhythmias V: Evaluating Dysrhythmias
Imaging Studies for Cardiovascular System I:Echocardiography
Indications: Echocardiography is utilized to diagnose heart failure, valve disorders, and myocardial infarction. It also assesses cardiac structures' size, shape, and motion,...
Exercise Stress Test
Exercise stress testing, commonly known as a treadmill test, is a noninvasive procedure used to evaluate cardiovascular function and diagnose heart conditions.
Definition
An exercise stress test measures the heart's response to exertion using a treadmill or stationary bicycle. Chest electrodes record the heart's electrical activity through an ECG, and blood pressure is monitored regularly.
Purposes