Related Experiment Video
Updated: May 4, 2026

Simple In-House Ultra-High Performance Capillary Column Manufacturing with the FlashPack Approach
Published on: December 4, 2021
Ultra high efficiency/low pressure supercritical fluid chromatography with superficially porous particles for
E Lesellier1, A Latos1, A Lopes de Oliveira2
1Institut de Chimie Organique et Analytique (ICOA), Université d'Orléans, CNRS UMR 7311, B.P. 6759, rue de Chartres, 45067 Orléans cedex 2, France.
Abstract:
This paper reports the development of the separation of vegetable oil triglycerides (TG) in supercritical chromatography (SFC), using superficially porous particles (SPPs). The SPP, having a small diameter (2-3μm), provide a higher theoretical plate number (N), which allows to improve separation of critical pairs of compounds. However, compared to fully porous particles of larger diameter (5μm), the pressure drop is also increased. Fortunately, supercritical fluids have a low viscosity, which allows coupling several columns to achieve high N values, while maintaining flow rate above 1ml/min, ensuring a ultra high efficiency (UHE) at low pressure (LP) (below 40MPa), with regards to the one reached with liquid and sub-two micron particles (around 100MPa). The use of two detector systems (UV and ELSD) connected in series to the UHE-LP-SFC system provides complementary responses, due to their specific detection principles. Working in a first part with three coupled Kinetex C18 columns (45cm total length), the effect of modifier nature and percentage were studied with two reference oils, argan and rapeseed, chosen for their different and well-known TG composition. The analytical method was developed from previous studies performed with fully porous particles (FPP). Optimized conditions with three Kinetex were as follows: 17°C, 12% of ACN/MeOH (90/10; v/v). With these conditions, and by using an increased length of Kinetex C18 column (60cm), another additional column was selected from ten different commercial SPP C18 bonded phases, by applying a Derringer function on varied parameters: theoretical plate number (TPN), separation index (SI) for critical pairs of peaks (the peaks of compounds difficult to separate due to subtle structural differences), the analysis duration, and the total peak number. This function normalizes the values of any parameters, between 0 and 1, from the worst value to the better, allowing to take account of various parameters in the final choice. Finally, by using four Kinetex C18 plus one Accucore C18 (75cm total column length), a high-performance separation of triglycerides was achieved, with reasonable analysis duration and isocratic conditions. These conditions can be applied to varied vegetable oils. Identification of the numerous separated peaks of rapeseed oil was achieved by using published data and chromatographic retention behaviour.
More Related Videos
11:44Qualitative Characterization of the Aqueous Fraction from Hydrothermal Liquefaction of Algae Using 2D Gas Chromatography with Time-of-flight Mass Spectrometry
Published on: March 6, 2016
12:47Tangential Flow Ultrafiltration: A “Green” Method for the Size Selection and Concentration of Colloidal Silver Nanoparticles
Published on: October 4, 2012
Related Concept Videos
Supercritical Fluid Chromatography
SFC utilizes a supercritical fluid mobile phase,...
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
High-Performance Liquid Chromatography: Instrumentation
High-Performance Liquid Chromatography: Elution Process
Size-Exclusion Chromatography
Silica particles offer advantages such as rigidity,...
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...