Related Experiment Video
Updated: May 4, 2026

Microsurgical Clip Obliteration of Middle Cerebral Aneurysm Using Intraoperative Flow Assessment
Published on: September 25, 2009
Flow artifact in the anterior communicating artery resembling aneurysm on the time of flight MR angiogram
Deepak Takhtani1, Sathish Dundamadappa2, Ajit S Puri2
1Department of Radiology, University of Massachusetts Medical School, UMass Memorial Hospital, Worcester, MA, USA deepak.takhtani@umassmemorial.org.
Background:
Magnetic resonance angiogram (MRA) of the brain is a widely employed non-invasive test to diagnose aneurysms. However, its overall accuracy is less than digital subtraction angiography and is prone to give false-positive or false-negative results. False-negative results can be seen with hemorrhage, lipoma, dermoid, posterior lobe of the pituitary gland, and the flow artifacts.
Purpose:
To describe the findings associated with false aneurysms in the anterior communicating artery on the time of flight MRA and review the physical principles behind this artifact.
Material And Methods:
This short series comprises of four patients whose MRA showed suspicious aneurysms in the region of the anterior communicating artery (ACOM) on time of flight MRA.
Results:
Two patients underwent catheter angiogram and the other two patients had computed tomography angiogram. None of these cases proved to have aneurysms and normal anterior communicating arteries were seen in all the patients. The findings on the MR angiograms were considered artifacts. All of the pseudoaneurysm had tapered appearance.
Conclusion:
MR angiogram can result in artifacts at ACOM which may be mistaken for aneurysm. Such pseudoaneurysms have characteristic appearance and should be followed up with non-invasive tests.
Insights
Time-of-flight MRA can create artifacts mimicking aneurysms in the anterior communicating artery (ACOM). These pseudoaneurysms have a tapered appearance and require further non-invasive testing for accurate diagnosis.
Area of Science:
- Neuroradiology
- Medical Imaging
- Vascular Imaging
Background:
- Magnetic Resonance Angiography (MRA) is a common non-invasive brain imaging technique for aneurysm detection.
- MRA accuracy is lower than digital subtraction angiography and susceptible to false positives/negatives.
- Potential causes of false negatives include hemorrhage, lipoma, dermoid, pituitary gland posterior lobe, and flow artifacts.
Purpose of the Study:
- To detail pseudoaneurysm findings on time-of-flight MRA in the anterior communicating artery (ACOM).
- To review the underlying physical principles of these MRA artifacts.
Main Methods:
- Analysis of four patients with suspected ACOM aneurysms on time-of-flight MRA.
- Follow-up imaging with catheter angiography or computed tomography angiography.
Main Results:
- No true aneurysms were confirmed in any of the four patients.
- All patients demonstrated normal anterior communicating arteries on confirmatory imaging.
- The suspicious findings on MRA were identified as artifacts, specifically pseudoaneurysms with a tapered appearance.
Conclusions:
- MRA can produce artifacts in the ACOM region that mimic aneurysms.
- These pseudoaneurysms possess a characteristic tapered appearance.
- Further non-invasive testing is recommended for suspected ACOM pseudoaneurysms identified on MRA.
Related Concept Videos
The Arch of Aorta
Encircling the heart, the coronary arteries form a ring-like structure before...
Aortic Regurgitation II: Clinical Features and Diagnostic Tests
Aneurysm II: Clinical Manifestations and Diagnostic Studies
Aneurysm I: Introduction
Magnetic Resonance Imaging

