Translational Rabbit Model of Chronic Cardiac Pacing
Published on: January 6, 2023
Managed ventricular pacing compared with conventional dual-chamber pacing for elective replacement in chronically
Giovanni L Botto1, Renato P Ricci2, Juan M Bénézet3
1S. Anna Hospital, Como, Italy.
Background:
Several studies have shown that unnecessary right ventricular pacing has detrimental effects.
Objective:
To evaluate whether minimization of ventricular pacing as compared with standard dual-chamber pacing (DDD) improves clinical outcomes in patients referred for pacemaker or implantable cardioverter-defibrillator (ICD) replacement.
Methods:
In an international single-blind, multicenter, randomized controlled trial, we compared DDD with managed ventricular pacing (MVP), a pacing mode developed to minimize ventricular pacing by promoting intrinsic atrioventricular conduction. We included patients referred for device replacement with >40% ventricular pacing, no cardiac resynchronization therapy upgrade indication, no permanent atrial fibrillation (AF), and no permanent complete atrioventricular block. Follow-up was for 2 years. The primary end point was cardiovascular hospitalization. The intention-to-treat analysis was performed by using Kaplan-Meier method and the log-rank test.
Results:
We randomized 605 patients (556 referred for pacemaker and 49 referred for ICD replacement; mean age 75 ± 11 years; 365 [60%] men, at 7.7 ± 3.3 years from first device implantation) to MVP (n = 299) or DDD (n = 306). We found no significant differences in the primary end point cardiovascular hospitalization (MVP: 16.3% vs DDD: 14.5%; P = .72) and the secondary end point persistent AF (MVP: 15.4% vs DDD: 11.2%; P = .08), permanent AF (MVP: 4.1% vs DDD: 3.1%; P = .44), and composite of death and cardiovascular hospitalization (MVP: 23.9% vs DDD: 20.2%; P = .48). MVP reduced right ventricular pacing (median 5% vs 86%; Wilcoxon, P < .0001) as compared with DDD.
Conclusions:
In patients referred for pacemaker and ICD replacement with clinically well-tolerated long-term exposure to >40% ventricular pacing in the ventricle, a strategy to minimize ventricular pacing is not superior to standard DDD in reducing incidence of cardiovascular hospitalizations.
More Related Videos
12:45Benefits of Cardiac Resynchronization Therapy in an Asynchronous Heart Failure Model Induced by Left Bundle Branch Ablation and Rapid Pacing
Published on: December 11, 2017
10:17Real-Time Cardiac Mapping with a Noninvasive Imageless Electrocardiographic Imaging System
Published on: April 11, 2025
Related Concept Videos
Cardiomyopathy II: Dilated Cardiomyopathy
Cardiomyopathy V: Interprofessional Care
Mitral Valve Prolapse II: Assessment and Management
Dysrhythmias VI: Management of Dysrhythmias
Mitral Regurgitation III: Medical Management
Cardiomyopathy III: Hypertrophic Cardiomyopathy