Related Experiment Video
Updated: May 4, 2026

Semi-automated Optical Heartbeat Analysis of Small Hearts
Published on: September 16, 2009
Automatic heart sound detection in pediatric patients without electrocardiogram reference via pseudo-affine
Ana Gavrovska1, Vesna Bogdanović2, Irini Reljin3
1Department of Telecommunications, School of Electrical Engineering, University of Belgrade, Bulevar kralja Aleksandra 73, 11120 Belgrade, Serbia; Innovation Center of the School of Electrical Engineering in Belgrade, University of Belgrade, Bulevar kralja Aleksandra 73, 11120 Belgrade, Serbia.
Abstract:
Having in mind the availability of electronic stethoscopes, phonocardiograms (PCGs) have become popular for cardiovascular functionality monitoring and signal processing applications. Detection of fundamental heart sounds (HSs), S1s and S2s, is considered to be a crucial step in PCG analysis. Electrocardiogram (ECG), noted as a reference signal, is often synchronously recorded in order to simplify the S1/S2 detection process. Nevertheless, electronic stethoscopes are frequently used without additional ECG equipment. We propose a new algorithm for automatic fundamental HSs detection via: joint time-frequency representation based on pseudo affine Wigner-Ville distribution (PAWVD), Haar wavelet lifting scheme (Haar-LS), normalized average Shannon energy (NASE) and autocorrelation. The performance of the proposed algorithm was calculated on both normal (50) and pathological (75) PCG recordings, eight seconds long each, contributed by 125 different pediatric patients. The algorithm showed relatively high recall (90.41%) and precision (96.39%) rates of S1/S2 detection procedure in a variety of PCG signals, without ECG as a reference. Furthermore, it indicated the ability to overcome splitting within the S1/S2 heart sounds.
More Related Videos
Related Concept Videos
Heart Sounds
Auscultation is the process of listening to these internal body sounds using a stethoscope. The heart produces four types of sounds, but only two—S1 and S2—can usually be heard with a stethoscope.
S1, also known as the "lub" sound, is caused by the closure of atrioventricular (A-V)...
Assessment of the Cardiovascular System IV: Auscultation
Normal Heart Sounds
S1 (First Heart Sound)-
S1 is made by the closure of the mitral and tricuspid valves (atrioventricular valves), marking the beginning of systole.
S2 (Second Heart Sound)-
S2 is made by the closure of the aortic and pulmonic valves (semilunar valves), marking the end of the systole.
Special considerations while measuring pulse
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:

