Detection of Architectural Distortion in Prior Mammograms via Analysis of Oriented Patterns
Published on: August 30, 2013
Mammography test sets: reading location and prior images do not affect group performance
B P Soh1, W B Lee2, M F McEntee3
1Medical Image Optimisation and Perception Group (MIOPeG), Discipline of Medical Radiation Sciences, University of Sydney, Sydney, NSW, Australia; Department of Diagnostic Radiology, Singapore General Hospital, Singapore.
Aim:
To examine how the location where reading takes place and the availability of prior images can affect performance in breast test-set reading.
Materials And Methods:
Under optimized viewing conditions, 10 expert screen readers each interpreted a reader-specific set of images containing 200 mammographic cases. Readers, randomly divided into two groups read images under one of two pairs of conditions: clinical read with prior images and laboratory read with prior images; laboratory read with prior images and laboratory read without prior images. Region-of-interest (ROI) figure-of-merit (FOM) was analysed using JAFROC software. Breast side-specific sensitivity and specificity were tested using Wilcoxon matched-pairs signed rank tests. Agreement between pairs of readings was measured using Kendall's coefficient of concordance.
Results:
Group performances between test-set readings demonstrated similar ROI FOMs, sensitivity and specificity median values, and acceptable levels of agreement between pairs of readings were shown (W = 0.75-0.79, p < 0.001) for both pairs of reading conditions. On an individual reader level, two readers demonstrated significant decreases (p < 0.05) in ROI FOMs when prior images were unavailable. Reading location had an inconsistent impact on individual performance.
Conclusion:
Reading location and availability of prior images did not significantly alter group performance.
Related Concept Videos
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies III: Computed Tomography
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Imaging Studies for Cardiovascular System IV: CMRI
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Imaging Studies IV: Magnetic Resonance Imaging