Related Experiment Video
Updated: May 4, 2026

Evaluation of Drug Sorption to PVC- and Non-PVC-based Tubes in Administration Sets Using a Pump
Published on: March 11, 2017
Physical and chemical compatibility of injectable acetaminophen during simulated y-site administration
Collin Anderson1, Sabrina Boehme2, Jacquelyn Ouellette3
1Clinical Pharmacist, Primary Children's Hospital;
Purpose:
The physical and chemical compatibility of intravenous acetaminophen with commonly administered injectable medications was evaluated.
Methods:
Simulated Y-site evaluation was accomplished by mixing 2 mL of acetaminophen (10 mg/mL) with 2 mL of an alternative intravenous medication and subsequently storing the mixture in a polypropylene syringe for 4 hours. The aliquot solutions were visually inspected and evaluated for crystal content at 4 hours by infusing 4 mL of the medication mixture through a 0.45-μm nitrocellulose filter disc. Medication mixtures that were selected for chemical stability testing were analyzed by high-performance liquid chromatography at 0, 1, and 4 hours using a Zorbax Eclipse Plus C18, 4.6 x 100 mm, 3.5-μm column for separation of analytes with subsequent diode-array detection. Medications were considered chemically compatible if the concentrations of all components were >90% of the original concentrations during the 4 hour simulated Y-site compatibility test.
Results:
U.S. Pharmacopeial Convention (USP) standards for physical particle counts were met for acetaminophen injection (10 mg/mL) when combined with cefoxitin, ceftriaxone, clindamycin, dexamethasone, diphenhydramine, dolasetron, fentanyl, granisetron, hydrocortisone, hydromorphone, ketorolac, meperidine, methylprednisolone, midazolam, morphine, nalbuphine, ondansetron, piperacillin/tazobactam, ranitidine, and vancomycin. Injectable acetaminophen is incompatible with acyclovir and diazepam and therefore should not be administered concomitantly with either of these products. Further testing confirmed the chemical compatibility of acetaminophen with ceftriaxone, diphenhydramine, granisetron, ketorolac, nalbuphine, ondansetron, piperacillin/tazobactam, and vancomycin.
Conclusion:
All medications tested with acetaminophen were physically compatible except for acyclovir and diazepam. All 8 medications tested for chemical compatibility with acetaminophen were stable over the 4 hour simulated Y-site administration study.
Related Concept Videos
Parenteral Drug Delivery Systems: Injectables, Implants, and Infusion Devices
Routes of Drug Administration: Parenteral
The intravenous route (IV) of drug administration can be further categorized into two types. The bolus injection administers the entire dose rapidly, while an intravenous infusion slowly delivers smaller doses steadily.
The IV route is often...
Factors Influencing Drug Absorption: Pharmaceutical Parameters
Phase II Reactions: Acetylation Reactions
The substrates for acetylation are typically drugs or their metabolites with an amino, sulfonamide, or hydrazine functional group. Acetylation can occur at several points in the drug molecule, including primary, secondary, and...
Drug Accumulation During Multiple Dosing: Repetitive IV Injections
Factors Influencing Drug Absorption: Physicochemical Parameters
Enhanced drug absorption can be achieved by reducing particle sizes and increasing surface areas, thereby facilitating...