Effect of the load size on the efficiency of microwave heating under stop flow and continuous flow conditions

Narendra G Patil1, Evgeny V Rebrov2, Kari Eränen3

  • 1Laboratory of Chemical Reactor Engineering, Eindhoven University of Technology, P.O.Box 513, 5600 MB Eindhoven, The Netherlands.

Related Concept Videos

Laminar Flow01:27

Laminar Flow

Laminar flow represents a smooth, orderly fluid motion where particles move along parallel paths, resulting in minimal mixing between layers. Streamlined particle paths characterize this flow regime and occur under conditions where viscous forces dominate over inertial forces. The distinction between laminar, transitional, and turbulent flow is primarily determined by the Reynolds number, a dimensionless quantity calculated as:
2.1K
Maximum Power Flow and Line Loadability01:23

Maximum Power Flow and Line Loadability

The maximum power flow for lossy transmission lines is derived using ABCD parameters in phasor form. These parameters create a matrix relationship between the sending-end and receiving-end voltages and currents, allowing the determination of the receiving-end current. This relationship facilitates calculating the complex power delivered to the receiving end, from which real and reactive power components are derived.
777
Standing Waves in a Cavity01:28

Standing Waves in a Cavity

A household microwave and lasers are examples of standing electromagnetic waves in a cavity. When two conducting metal plates are placed parallel at the nodal planes, it creates a cavity where standing waves are formed. The cavity between the two planes is analogous to a stretched string held at the points x = 0 and x = L. Here, the distance 'L' between the two planes must be an integer multiple of half of the wavelength. The wavelengths that satisfy this condition are given by:
1.7K
Steady Flow of a Fluid Stream01:27

Steady Flow of a Fluid Stream

Consider a control volume, such as a pipe with solid boundaries, through which fluid flows and changes direction due to the impulse exerted by the resulting force from the pipe walls. In steady flow, the mass of fluid entering the control volume at a given time, t, with velocity v1, is equal to the mass leaving after infinitesimal time dt, with velocity v2.
During this process, the momentum of the fluid within the control volume remains constant over the time interval dt. By applying the...
972
Continuity Equation01:28

Continuity Equation

The continuity equation asserts that the mass flow rate must remain constant for a steady flow of an incompressible fluid within a confined system. This principle applies to systems where fluid passes through varying cross-sectional areas, such as nozzles, syringes, and pipes.
The mass flow rate is expressed as:
3.5K
Conservation of Mass in Fixed, Nondeforming Control Volume01:07

Conservation of Mass in Fixed, Nondeforming Control Volume

The principle of conservation of mass is fundamental in fluid dynamics and is crucial for analyzing flow within fixed control volumes, such as pipes or ducts. This principle states that the total mass within a control volume remains constant unless altered by the inflow or outflow of mass through the control surfaces. This results in a vital relationship for steady, incompressible flow where the mass entering a system equals the mass leaving it.
In the case of a sewer pipe, which can be modeled...
1.4K