Pulse Wave Velocity Testing in the Baltimore Longitudinal Study of Aging
Published on: February 7, 2014
Validity and reliability of aortic pulse wave velocity and augmentation index determined by the new cuff-based
M H Hwang1, J K Yoo1, H K Kim1
1Department of Applied Physiology and Kinesiology, University of Florida, Gainesville, FL, USA.
Abstract:
Aortic pulse wave velocity (AoPWV) and augmentation index (AIx) are commonly used measures of large elastic artery stiffness and wave reflection, respectively. Recently, a new cuff-based SphygmoCor device (Xcel) has been developed to measure both AoPWV and AIx. We sought to examine the following: (1) the validity of Xcel compared with the well-validated tonometry-based SphygmoCor device (MM3); (2) the intratest and day-to-day reliability of Xcel; (3) the influence of body side (right or left) on Xcel measurements; and (4) the relation of Xcel measurements to carotid artery compliance, distensibility and β-stiffness index. We found that measurements of AoPWV and AIx between Xcel and MM3 were not different (P=0.26 and P=0.43, N=22 and 26, respectively) and were strongly related (r=0.85 and 0.75, P<0.0001), and based on Bland-Altman plots there was good agreement between them. Intra-test (intraclass correlation=0.996 and 0.983, P<0.0001; AoPWV and AIx, N=24 and 26, respectively) and day-to-day reliability (intraclass correlation=0.979 and 0.939, P<0.0001) were high. Xcel AoPWV and AIx on the left versus right body side were not different (P=0.19 and P=0.58, N=14 and 15, respectively) and were highly correlated (r=0.99 and 0.94, P<0.0001). AoPWV and AIx measured with Xcel were positively related with β-stiffness index (r=0.62 and 0.51, P< or = 0.005, N=23 and 24, respectively) and negatively related with distensibility (r = -0.58 and -0.44, P < or = 0.02, N=23 and 24, respectively). In conclusion, Xcel measures of AIx and AoPWV are valid, highly reliable and not affected by body side. Xcel is a useful tool for use in research and the clinic.
Related Concept Videos
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Assessment of blood pressure in brachial artery(two-step method)
Pulse
The pulse serves as a clinical...
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.