Related Experiment Video
Updated: May 4, 2026

Establishment of a Novel Ex Vivo Lung Perfusion System for Rat Lungs After Circulatory Death
Published on: October 18, 2024
Successful prolonged ex vivo lung perfusion for graft preservation in rats
Kentaro Noda1, Norihisa Shigemura, Yugo Tanaka
1Department of Cardiothoracic Surgery, University of Pittsburgh, Pittsburgh, PA, USA.
Objectives:
Ex vivo lung perfusion (EVLP) strategies represent a new frontier in lung transplantation technology, and there have been many clinical studies of EVLP in lung transplantation. The establishment of a reliable EVLP model in small animals is crucial to facilitating translational research using an EVLP strategy. The main objective of this study was to develop a reproducible rat EVLP (R-EVLP) model that enables prolonged evaluation of the explanted lung during EVLP and successful transplantation after EVLP.
Methods:
The donor heart-lung blocks were procured with cold low-potassium dextran solution and immersed in the solution for 1 h at 4 °C. And then, the heart-lung blocks were flushed retrogradely and warmed up to 37 °C in a circuit perfused antegradely with acellular perfusate. The perfusate was deoxygenated with a gas mixture (6% O2, 8% CO2, 86% N2). The perfusion flow was maintained at 20% of the entire cardiac output. At 37 °C, the lungs were mechanically ventilated and perfusion continued for 4 h. Every hour, the perfused lung was evaluated for gas exchange, dynamic lung compliance (Cdyn) and pulmonary vascular resistance (PVR).
Results:
R-EVLP was performed for 4 h. Pulmonary oxygenation ability (pO2/pCO2) was stable for 4 h during EVLP. It was noted that Cdyn and PVR were also stable. After 4 h of EVLP, pO2 was 303 ± 19 mmHg, pCO2 was 39.6 ± 1.2 mmHg, PVR was 1.75 ± 0.10 mmHg/ml/min and Cdyn was 0.37 ± 0.03 ml/cmH2O. Lungs that were transplanted after 2 h of R-EVLP resulted in significantly better post-transplant oxygenation and compliance when compared with those after standard cold static preservation.
Conclusions:
Our R-EVLP model maintained stable lung oxygenation, compliance and vascular resistance for up to 4 h of perfusion duration. This reliable model should facilitate further advancement of experimental work using EVLP.