Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Determination of Multiple Dosing Parameters: Loading and Maintenance Doses01:25

Determination of Multiple Dosing Parameters: Loading and Maintenance Doses

394
A loading dose is an essential pharmacological strategy to rapidly achieve the target plasma drug concentration necessary for an immediate therapeutic effect. This approach is especially critical for drugs characterized by slow absorption or extended half-lives, where delaying therapeutic plasma levels could compromise treatment outcomes. By administering a loading dose, clinicians ensure a prompt onset of drug action, even for agents with complex pharmacokinetic profiles.Achieving steady-state...
394
Dose Size and Dosing Frequency: Determination Methods01:21

Dose Size and Dosing Frequency: Determination Methods

804
Determining the optimal dose size and dosing frequency in pharmacotherapy is crucial for achieving therapeutic effectiveness while minimizing adverse effects. This article explores the methodologies employed in determining these parameters, focusing on their significance and interplay to tailor dosing regimens.Dose Size: Dose size refers to the amount of a drug administered in a single dose. It is determined based on the drug's pharmacodynamics and pharmacokinetics properties and...
804
Dosage Regimens: Designs and Approaches01:28

Dosage Regimens: Designs and Approaches

600
Designing a dosage regimen, which refers to the manner of drug administration, is a complex process involving the selection of drug dose, route, and frequency. This process is underpinned by pharmacokinetic parameters derived from tests and population averages. These parameters are then tailored to patient-specific variables such as diagnosis, demographics, and allergy status. Once therapy commences, therapeutic response monitoring is critical and achieved through clinical and physical...
600
Methods of Medium Optimization01:28

Methods of Medium Optimization

70
Optimizing growth media enhances microbial proliferation and maximizes product yield. Statistical experimental design methodologies provide structured and reproducible approaches, offering progressively higher levels of robustness and efficiency.The One-Factor-at-a-Time (OFAT) MethodThe One-Factor-at-a-Time (OFAT) method involves adjusting a single variable while keeping all others constant. However, it cannot detect interactions between variables, often leading to suboptimal outcomes when...
70
Dosage Regimen Designs: Nomograms and Tabulations01:23

Dosage Regimen Designs: Nomograms and Tabulations

353
Nomograms and tabulations are vital tools used by clinicians to design accurate and individualized dosage regimens. These instruments provide a straightforward method for adjusting dosages based on individual patient characteristics, including age, weight, and physiological condition. The foundation of a drug's nomogram is population pharmacokinetic data collected and analyzed using specific models. This data simplifies complex equations, presenting them diagrammatically or tabularly for easy...
353
Radiation: Applications01:17

Radiation: Applications

1.8K
The average temperature of Earth is the subject of much current discussion. Earth is in radiative contact with both the Sun and dark space; it receives almost all its energy from the radiation of the Sun and reflects some of it into outer space. Dark space is very cold, about 3 K, so Earth radiates energy into it. For instance, heat transfer occurs from soil and grasses, the rate of which can be so rapid that frost can occur on clear summer evenings, even in warm latitudes.
The average...
1.8K

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Experimentally determined proton discrete spot scanning time structures for an improved synchrotron-based PBS spot delivery time model.

Medical physics·2026
Same author

Alpha DaRT source activity confirmation using a reentrant well-type ionization chamber.

Medical physics·2026
Same author

A prospective risk analysis for the clinical commissioning of a dose-driven continuous scanning proton therapy system.

Frontiers in oncology·2026
Same author

Comparative evaluation of the Mayo Clinic Florida microdosimetric kinetic model and mMKM for carbon ion treatment planning: A matRad-based analysis.

Journal of applied clinical medical physics·2026
Same author

Fluoroscopy-Guided Motion Management in Particle Therapy: Evolution, Challenges, and AI-Enabled Opportunities.

Tomography (Ann Arbor, Mich.)·2026
Same author

Automated needle reconstruction for HDR prostate brachytherapy using a commercially compatible 3D-printed transrectal ultrasound sleeve with integrated EM tracking sensors.

Brachytherapy·2026

Related Experiment Video

Updated: May 3, 2026

Proton Therapy Delivery and Its Clinical Application in Select Solid Tumor Malignancies
08:34

Proton Therapy Delivery and Its Clinical Application in Select Solid Tumor Malignancies

Published on: February 6, 2019

20.6K

Quality assurance for high dose rate brachytherapy treatment planning optimization: using a simple optimization to

Christopher L Deufel1, Keith M Furutani

  • 1Department of Radiation Oncology, Mayo Clinic, Rochester, MN 55905, USA.

Physics in Medicine and Biology
|January 18, 2014
PubMed
Summary

A simple brachytherapy optimization method offers quality assurance for complex systems. This approach verifies treatment planning system results, ensuring accuracy and identifying potential errors in high dose rate brachytherapy.

More Related Videos

Radiation Planning Assistant - A Streamlined, Fully Automated Radiotherapy Treatment Planning System
08:25

Radiation Planning Assistant - A Streamlined, Fully Automated Radiotherapy Treatment Planning System

Published on: April 11, 2018

17.7K
Author Spotlight: Improving Radiation Therapy Access with Radiation Planning Assistant
05:18

Author Spotlight: Improving Radiation Therapy Access with Radiation Planning Assistant

Published on: October 6, 2023

2.1K

Related Experiment Videos

Last Updated: May 3, 2026

Proton Therapy Delivery and Its Clinical Application in Select Solid Tumor Malignancies
08:34

Proton Therapy Delivery and Its Clinical Application in Select Solid Tumor Malignancies

Published on: February 6, 2019

20.6K
Radiation Planning Assistant - A Streamlined, Fully Automated Radiotherapy Treatment Planning System
08:25

Radiation Planning Assistant - A Streamlined, Fully Automated Radiotherapy Treatment Planning System

Published on: April 11, 2018

17.7K
Author Spotlight: Improving Radiation Therapy Access with Radiation Planning Assistant
05:18

Author Spotlight: Improving Radiation Therapy Access with Radiation Planning Assistant

Published on: October 6, 2023

2.1K

Area of Science:

  • Medical Physics
  • Radiation Oncology

Background:

  • High dose rate (HDR) brachytherapy dose optimization is increasingly complex.
  • Verifying the reasonableness of optimization results is crucial for patient safety and treatment efficacy.

Purpose of the Study:

  • To present a simple optimization method for quality assurance (QA) of complex commercial brachytherapy treatment planning systems (TPS).
  • To evaluate the effectiveness of this simple method in identifying potential TPS failures or operator errors.

Main Methods:

  • Developed a simple, exact, variance-based, algebraic optimization method.
  • Optimized conformal target coverage for various clinical applications (breast, cervix, prostate, planar applicators).
  • Compared key dosimetric metrics (dose volume histogram, conformality index, total reference air kerma) between simple and complex optimizations.

Main Results:

  • The simple optimization method demonstrated close agreement with complex commercial TPS optimizations for multiple applicator types.
  • The method proved sensitive in detecting failures within commercial TPS, attributable to operator error or algorithm weaknesses.
  • Dosimetric outcomes from the simple method were surprisingly similar to those from sophisticated commercial optimization algorithms.

Conclusions:

  • A simple algebraic optimization serves as an effective QA tool for HDR brachytherapy TPS.
  • The complexity of current brachytherapy optimization algorithms may yield only modest gains in source strength distributions.