Related Experiment Video
Updated: May 3, 2026

Analyzing Protein Architectures and Protein-Ligand Complexes by Integrative Structural Mass Spectrometry
Published on: October 15, 2018
Development and investigation of a mesh-electrode linear ion trap (ME-LIT) mass analyzer
Liang Wang1, Fuxing Xu, Xinhua Dai
1Department of Chemistry and Laser Chemistry Institute, Fudan University, Shanghai, China.
Abstract:
A mesh-electrode linear ion trap (ME-LIT) mass analyzer was developed and its performance was primarily characterized. In conventional linear ion trap mass analyzers, the trapped ions are mass-selected and then ejected in a radial direction by a slot on a trap electrode. The presence of slots can strongly affect the electric field distribution in the ion trapping region and distort the mass analysis performance. To compensate for detrimental electric field effects, the slot is usually designed and fabricated to be as small as possible, and also has very high mechanical accuracy and symmetry. A ME-LIT with several mesh electrodes was built to compensate for the effects caused by slots. Each mesh electrode was fabricated from a plate electrode with a relatively large slot and the slot was covered with a conductive mesh. Our preliminary experimental results show that the ME-LIT could considerably diminish the detrimental electric field effects caused by slots, and increase the mass resolving power and ion detection efficiency. Even with 4-mm-wide slots, a mass resolution in excess of 600 was obtained using the ME-LIT. Mass resolution could be remarkably improved using mesh electrodes in ion traps with asymmetric electrodes. The stability diagram of the ME-LIT was mapped, and highly efficient tandem mass spectrometry was demonstrated. The ME-LIT was qualified as a LIT mass analyzer. The ME-LIT can improve the mass resolution and decrease the requirements of mechanical accuracy and symmetry of slots, so it shows potential for a wide range of practical uses.
More Related Videos
09:38Dithranol as a Matrix for Matrix Assisted Laser Desorption/Ionization Imaging on a Fourier Transform Ion Cyclotron Resonance Mass Spectrometer
Published on: November 26, 2013
10:47Whole-body Mass Spectrometry Imaging by Infrared Matrix-assisted Laser Desorption Electrospray Ionization IR-MALDESI
Published on: March 24, 2016
Related Concept Videos
Mass Analyzers: Common Types
Matrix-Assisted Laser Desorption Ionization (MALDI)
Mass Analyzers: Overview
MALDI-TOF Mass Spectrometry
Mass Spectrometers
Electrospray Ionization (ESI) Mass Spectrometry
ESI utilizes electrical energy to transfer ions from the liquid phase of the sample into the...