Characteristics of electrically injured skin from human hand tissue samples using Fourier transform infrared
Shi-Ying Li1, Dong-Hua Zou2, Yi-Wen Luo3
1Department of Forensic Pathology, Institute of Forensic Science, Ministry of Justice, 200063, Shanghai, P.R. China; Department of Forensic Medicine, Shanghai Medical College, Fudan University, 200032, Shanghai, P.R. China.
Abstract:
This technical note describes a method for distinguishing normal skin tissue samples from those electrically injured by Fourier transform infrared microspectroscopy (FTIR MSP). Furthermore, the infrared spectral features of electrically injured cells and tissues were evaluated to identify molecular changes in epidermal cells. In the present study, 20 human hand tissue samples were evaluated macroscopically and histopathologically. The electrically injured skin samples were subdivided into 2 regions [normal cell regions (NCRs) and polarized cell regions (PCRs)] and 14 major spectral absorption bands were selected. The spectral results showed that the band absorbance at 1080, 1126, 1172, 1242, 1307, 1403, 1456, 1541, 2852, 2925, 2957, 3075, and 3300cm(-1) increased significantly both in the stratum and non-stratum corneum of the PCRs in electrically injured skin tissues samples. No significant difference was found between normal skin and the NCR of the electrically injured skin samples. The band absorbance ratios of A1172/A1126, A1456/A1403, and A2925/A2957 were significantly increased, whereas the A1652/A1541 ratio was decreased in the PCR of the stratum corneum and non-stratum corneum. Baseline changes from 4000 to near 1737cm(-1) were observed in the spectra of the electrically injured skin samples, which were interpreted in terms of the pathological process involved in electrical injury. FTIR-MSP presents a useful method to provide objective spectral markers for the assisted diagnosis of electrical marks.
More Related Videos
Related Concept Videos
IR Frequency Region: Fingerprint Region
Infrared (IR) Spectroscopy: Overview
Different compounds display unique properties due to their...
IR Spectrometers
IR Spectrum
Transmittance is defined as the ratio of the radiant power passing through a sample to that from the radiation's source. Multiplying the transmittance by 100 gives the percent transmittance (%T), which varies between 100% (no absorption) and 0%...
Attenuated Total Reflectance (ATR) Infrared Spectroscopy: Overview
The ATR process begins by directing a beam...
Burn Injuries
The damage results in the death of skin cells, which can lead to a massive loss of fluid. Dehydration, electrolyte imbalance, and renal and circulatory failure follow, which can be fatal. Burn patients are treated with intravenous fluids to offset...