Related Experiment Video
Updated: May 2, 2026

Fabrication of Electrochemical-DNA Biosensors for the Reagentless Detection of Nucleic Acids, Proteins and Small Molecules
Published on: June 1, 2011
Electrochemiluminescence aptasensor based on bipolar electrode for detection of adenosine in cancer cells
Hai-Wei Shi1, Mei-Sheng Wu1, Ying Du2
1State Key Laboratory of Analytical Chemistry for Life Science, School of Chemistry and Chemical Engineering, Nanjing University, Nanjing 210093, China.
Abstract:
Here we report a novel approach for the detection of adenosine in cancer cells by electrochemiluminescence (ECL) on a wireless indium tin oxide bipolar electrode (BPE). In this approach, ferrocene (Fc) which is labeled on adenosine aptamer is enriched on one pole of the BPE by hybridization with its complementary DNA (ssDNA) and oxidized to Fc(+) under an external voltage of 5.0V at the two ends of BPE. Then, a reversed external voltage was added on the BPE, making Fc(+) enriched pole as cathode. The presence of Fc(+) promotes the oxidation reaction on the anodic pole of the BPE, resulting in a significant increase of ECL intensity using Ru(bpy)3(2+)/tripropylamine (TPA) system as test solution. The presence of target adenosine was reflected by the ECL signal decrease on the anodic pole caused by the target-induced removal of ferrocene-aptamer on the cathodic pole. The decrease of ECL signal was logarithmically linear with the concentration of ATP in a wide range from 1.0 fM to 0.10 μM. This ECL biosensing system could accurately detect the level of adenosine released from cancer cells.