Abstract:
Breath tests are non-invasive, non-radioactive, safe, simple and effective tests able to determine significant metabolic alterations due to specific diseases or lack of specific enzymes. Carbon isotope (13)C, the stable-non radioactive isotope of carbon, is the most used substrate in breath testing, in which (13)C/(12)C ratio is measured and expressed as a delta value, a differences between readings and a fixed standard. (13)C/(12)C ratio is measured with isotope ratio mass spectrometry or non-dispersive isotope-selective infrared spectrometer and generally there is a good agreement between these techniques in the isotope ratio estimation. (13)C/(12)C ratio can be expressed as static measurement (like delta over baseline in urea breath test) or as dynamic measurement as percent dose recovery, but more dosages are necessary. (13)C Breath-tests are involved in many fields of interest within gastroenterology, such as detection of Helicobacter pylori infection, study of gastric emptying, assessment of liver and exocrine pancreatic functions, determination of oro-caecal transit time, evaluation of absorption and to a lesser extend detection of bacterial overgrowth. The use of every single test in a clinical setting is vary depending on accuracy and substrate costs. This review is meant to present (13)C the meaning of (13)C/(12)C ratio and static and dynamic measure and, finally, the instruments dedicated to its use in gastroenterology. A brief presentation of (13)C breath tests in gastroenterology is also provided.
More Related Videos
09:19Capturing Actively Produced Microbial Volatile Organic Compounds from Human-Associated Samples with Vacuum-Assisted Sorbent Extraction
Published on: June 1, 2022
12:24Assessment of Gastric Emptying in Non-obese Diabetic Mice Using a [13C]-octanoic Acid Breath Test
Published on: March 23, 2013
Related Concept Videos
Serum Laboratory Studies, Stool Test, Breath Test
Imaging Studies III: Gastrointestinal Motility Studies and Virtual Colonoscopy
Radionuclide Testing
Radionuclide testing is a sophisticated medical technique for assessing gastrointestinal motility. It focuses on gastric emptying and colonic transit time. Radioactive markers track the movement of food through the digestive system, providing insights into gastrointestinal disorders.
In gastric emptying studies, a meal's liquid and...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
¹³C NMR: Distortionless Enhancement by Polarization Transfer (DEPT)