Related Experiment Video
Updated: May 3, 2026

In Vivo Immunofluorescence Localization for Assessment of Therapeutic and Diagnostic Antibody Biodistribution in Cancer Research
Published on: September 16, 2019
Numerical comparison of iodine-based and indium-based antibody biodistributions
Lawrence E Williams1, Anna M Wu, Vania E Kenanova
11 Division of Diagnostic Radiology, City of Hope National Medical Center , Duarte, California.
Purpose:
Single-step iodination is often performed in preference to use of a radiometal label for initial animal biodistributions. Yet loss of iodine occurs in vivo so that it is important to measure uptake (%ID/g) differences between radiolabels.
Methods:
Murine biodistributions of four radioiodinated and (111)In-labeled cognate anti-carcinoembryonic antigen antibodies were compared. Uptakes were obtained in athymic mice out to 96 hours for diabody, minibody, scFv-Fc, and intact humanized (M5A) versions of the T84.66 antibody. Tissues included liver, spleen, kidneys, lungs, and human LS174T colorectal xenografts. Ratios (R) of iodine uptake to indium uptake were calculated.
Results:
For all cognates, no significant differences were found in the blood uptakes between the two labels. In normal solid organs, iodine was generally cleared more rapidly with decreasing molecular weight (MW). In liver and spleen by 24 hours, the R value was 5% for diabody and minibody, whereas a value of 50% was seen for the intact mAb. Renal differences were even more marked for the two lower MW species. Tumor losses, however, were found to be essentially independent of MW and were modest; 50% by 48 hours. To test the generality of the results, comparisons were then made for normal organs and tumors of the R values found above for M5A and MN-14 intact antibody literature results. Good agreement, within estimated errors in R, was seen between these two cases, although (111)In and (88)Y were the respective radiometals.
Conclusions:
Loss of iodine from labeled antibodies can be marked in normal organs and that correction (by 1/R) of the iodine biodistribution to estimate the associated radiometal result may be possible. Explicit differences between the two types of biodistribution also imply that separate uptake results need to be considered when evaluating the impact on imaging and therapy using various possible radiolabels.
More Related Videos
07:25In Vitro Methods for Comparing Target Binding and CDC Induction Between Therapeutic Antibodies: Applications in Biosimilarity Analysis
Published on: May 4, 2017
08:47Synthesis and Bioconjugation of Thiol-Reactive Reagents for the Creation of Site-Selectively Modified Immunoconjugates
Published on: March 6, 2019