Related Experiment Video
Updated: May 3, 2026

Evaluation of Left Ventricular Structure and Function using 3D Echocardiography
Published on: October 28, 2020
Utility of real-time three-dimensional echocardiography for Duchenne muscular dystrophy with echocardiographic
Rie S Tsuburaya1, Hiroshi Uchizumi2, Michio Ueda3
1Department of Pediatric Neurology, National Hospital Organization Utano Hospital, Kyoto, Japan.
Insights
Real-time three-dimensional echocardiography accurately measures left ventricular ejection fraction in Duchenne muscular dystrophy (DMD) patients. This advanced imaging technique overcomes limitations of traditional echocardiography for assessing cardiac function in DMD.
Area of Science:
- Cardiology
- Medical Imaging
- Genetics
Background:
- Duchenne muscular dystrophy (DMD) frequently causes dilated cardiomyopathy, a leading cause of mortality.
- Cardiac dysfunction requires regular monitoring and early intervention in DMD patients.
- Traditional 2D echocardiography has limitations in quantifying cardiac function in DMD due to thoracic deformities and regional wall motion abnormalities.
Purpose of the Study:
- To evaluate the accuracy of real-time three-dimensional echocardiography (RT3DE) for assessing left ventricular ejection fraction (LVEF) in DMD patients.
- To compare RT3DE-derived LVEF with established nuclear cardiology methods.
Main Methods:
- Seventeen male DMD patients were assessed using RT3DE.
- LVEF was measured by RT3DE and compared with radionuclide angiocardiography (first-pass method) and quantitative ECG-gated SPECT.
Main Results:
- RT3DE showed a good correlation with LVEF values obtained by nuclear cardiology methods.
- A particularly strong correlation (r=0.90, p<0.05) was found between RT3DE and the first-pass radionuclide angiocardiography method.
- RT3DE provides accurate LVEF measurements even in DMD patients with echocardiographic challenges.
Conclusions:
- RT3DE is a feasible and accurate tool for assessing LVEF in DMD patients.
- This technology can overcome the limitations of conventional echocardiography in this population.
- RT3DE may improve the cardiac assessment and management of DMD patients.
Abstract:
Duchenne muscular dystrophy (DMD) is strongly associated with a unique form of dilated cardiomyopathy. Cardiac complications are the leading cause of death in DMD; thus, longitudinal assessments and early intervention for cardiac dysfunction are necessary to improve prognosis. Two-dimensional echocardiography, which is routinely used for cardiac assessment, has some limitations for quantitative analyses in DMD patients with thoracic deformities and regional wall motion abnormalities in the left ventricle. Recently, real-time three-dimensional echocardiography has emerged as a feasible tool for cardiac assessment in various cardiac diseases. The aim of this study was to examine the utility of this technology in DMD. We evaluated left ventricular ejection fraction (LVEF), a major parameter of left ventricular function, in 17 male DMD patients. LVEF values measured by real-time three-dimensional echocardiography were compared with those determined by two established nuclear cardiology methods: "the first-pass method of radionuclide angiocardiography" and "quantitative electrocardiogram-gated single-photon emission computed tomography". A good correlation was observed for LVEF values, particularly between real-time three-dimensional echocardiography and "the first-pass method of radionuclide angiocardiography" (r=0.90, p<0.05). Thus, real-time three-dimensional echocardiography can provide an accurate measurement of LVEF in DMD patients with echocardiographic limitations.
More Related Videos
07:11Morphological and Functional Assessment of the Right Ventricle Using 3D Echocardiography
Published on: October 28, 2020
09:05Assessment of Cardiac Morphological and Functional Changes in Mouse Model of Transverse Aortic Constriction by Echocardiographic Imaging
Published on: June 21, 2016