Applanation tonometry: a reliable technique to assess aortic pulse wave velocity in spinal cord injury
K D Currie1, M Hubli1, A V Krassioukov2
1International Collaboration on Repair Discoveries (ICORD), Department of Medicine, University of British Columbia, Vancouver, British Columbia, Canada.
Study Design:
Within-subject repeated measures.
Objectives:
To determine the intra- and inter-tester reliability of aortic pulse wave velocity (aPWV) measurements collected using applanation tonometry in individuals with spinal cord injury (SCI).
Setting:
Inpatient Rehabilitation Centre and outpatient Clinic in Vancouver, BC, Canada.
Methods:
Fifteen men and three women with traumatic SCI (age: 46±16 years; C3-L1; American Spinal Injury Association Impairment Scale A-D; 2-284 months post injury) participated in two testing sessions separated by an average of 2 days. During each testing session, aPWV measurements were collected in the supine position following 10 min of rest. Arterial blood pressure waveforms were collected simultaneously by two trained raters at the carotid and femoral arterial sites using applanation tonometry. Heart rate was continuously measured using a single-lead electrocardiogram, whereas brachial blood pressures were measured at 5-min intervals using an automated device.
Results:
Intra- and inter-tester aPWV measurements demonstrated almost perfect reliability with intraclass correlation coefficients of 0.91 and 0.98 (P<0.001), and coefficients of variation of 5.9% and 3.4%, respectively. The smallest detectable differences (SDDs) for intra- and inter-tester measurements were 0.9 m s(-1) and 0.6 m s(-1), respectively. There were no significant differences in heart rate or blood pressure between intra- and inter-testing sessions.
Conclusion:
Applanation tonometry measurements of aPWV are reliable in individuals with SCI. In addition, the SDDs were smaller than a clinically relevant value, suggesting that this measurement is suitable for repeated measures study designs in SCI.
Related Concept Videos
Peripheral Arterial Disease II: Clinical Manifestations and Diagnostic Evaluation
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Assessment of blood pressure in brachial artery(two-step method)
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation
Assessment of apical pulse
Assessing the apical pulse is a critical nursing procedure, particularly indicated for: