Related Experiment Video
Updated: May 3, 2026

Cardiac Magnetic Resonance for the Evaluation of Suspected Cardiac Thrombus: Conventional and Emerging Techniques
Published on: June 11, 2019
Safety and tolerability of regadenoson CMR
Kim-Lien Nguyen1, W Patricia Bandettini2, Sujata Shanbhag2
1Cardiovascular and Pulmonary Branch, National Heart, Lung and Blood Institute, National Institutes of Health, 10 Center Drive Bldg 10, Rm B1D416, MSC 1061, Bethesda, MD 20892-1061, USA Division of Cardiology, David Geffen School of Medicine at UCLA, Los Angeles, CA 90073, USA.
Aims:
Knowledge of adverse events associated with regadenoson perfusion cardiac magnetic resonance (CMR) and patient tolerability has implications for patient safety and staff training. We sought to assess the safety and tolerability of regadenoson stress CMR.
Materials And Methods:
A group of 728 consecutive patients (median age 58, 44% female) and 25 normal volunteers (median age 21, 24% female) were recruited from August 2009 to March 2012 using a prospective, cross-sectional study design. Subjects were stressed using fixed-dose regadenoson and imaged using a 1.5T MRI scanner. Symptoms and adverse events including death, myocardial infarction (MI), ventricular tachycardia (VT)/ventricular fibrillation (VF), hospitalization, arrhythmias, and haemodynamic stability were assessed.
Results:
There were no occurrences of death, MI, VT/VF, high-grade atrioventricular block, or stress-induced atrial fibrillation. Notable adverse events included one case of bronchospasm and one case of heart failure exacerbation resulting in hospitalization. The most common symptoms in patients were dyspnoea (30%, n = 217), chest discomfort (27%, n = 200), and headache (15%, n = 111). There was minimal change between baseline and peak systolic and diastolic blood pressure in both patients and volunteers (P > 0.05). A blunted heart rate response to regadenoson was noted in patients with body mass index (BMI) ≥ 30 kg/m(2) (P < 0.001), and diabetes (P = 0.001).
Conclusions:
Regadenoson CMR is well tolerated and can be performed safely with few adverse events.
More Related Videos
10:26A Multicenter MRI Protocol for the Evaluation and Quantification of Deep Vein Thrombosis
Published on: June 2, 2015
06:08Assessment of Chimeric Antigen Receptor T Cell-Associated Toxicities Using an Acute Lymphoblastic Leukemia Patient-Derived Xenograft Mouse Model
Published on: February 10, 2023
Related Concept Videos
Imaging Studies for Cardiovascular System IV: CMRI
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies for Cardiovascular System V: CT
Radiological Investigation I: X-ray and CT
Imaging Studies III: Computed Tomography
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...