Synthesis of trigeneration systems: sensitivity analyses and resilience

Monica Carvalho1, Miguel A Lozano2, José Ramos2

  • 1Department of Renewable Energy Engineering, Center of Alternative and Renewable Energy, Federal University of Paraíba, Campus I, 58059-970 João Pessoa, PB, Brazil.

Thescientificworldjournal
|January 24, 2014
PubMed

Related Concept Videos

Power System Three-Phase Short Circuits01:21

Power System Three-Phase Short Circuits

Determining the subtransient fault current in a power system involves representing transformers by their leakage reactances, transmission lines by their equivalent series reactances, and synchronous machines as constant voltage sources behind their subtransient reactances. In this analysis, certain elements are excluded, such as winding resistances, series resistances, shunt admittances, delta-Y phase shifts, armature resistance, saturation, saliency, non-rotating impedance loads, and small...
742
Multimachine Stability01:25

Multimachine Stability

Multimachine stability analysis is crucial for understanding the dynamics and stability of power systems with multiple synchronous machines. The objective is to solve the swing equations for a network of M machines connected to an N-bus power system.
In analyzing the system, the nodal equations represent the relationship between bus voltages, machine voltages, and machine currents. The nodal equation is given by:
698
Simplified Synchronous Machine Model01:30

Simplified Synchronous Machine Model

The Synchronous Machine Model is a fundamental tool in analyzing and ensuring the transient stability of power systems. This model simplifies the representation of a synchronous machine under balanced three-phase positive-sequence conditions, assuming constant excitation and ignoring losses and saturation. The model is pivotal for understanding the behavior of synchronous generators connected to a power grid, particularly during transient events.
In this model, each generator is connected to a...
1.0K
Energy Losses in Transformers01:21

Energy Losses in Transformers

In an ideal transformer, it is assumed that there are no energy losses, and, hence, all the power at the primary winding is transferred to the secondary winding. However, in reality,  the transformers always have some energy losses, and, hence, the output power obtained at the secondary winding is less than the input power at the primary winding due to energy losses.
There are four main reasons for energy losses in transformers.
The first cause can be  the high resistance of the...
1.6K
Transient and Steady-state Response01:24

Transient and Steady-state Response

In control systems, test signals are essential for evaluating performance under various conditions. The ramp function is effective for systems undergoing gradual changes, while the step function is suitable for assessing systems facing sudden disturbances. For systems subjected to shock inputs, the impulse function is the most appropriate test signal.
These test signals are integral in designing control systems to exhibit two key performance aspects: transient response and steady-state...
756
Wind Turbine Machine Models01:24

Wind Turbine Machine Models

In the growing field of wind energy, incorporating wind turbine models into transient stability analysis is essential. Induction and synchronous machines are the primary models used, with induction machines being prevalent due to their simplicity and reliability.
Induction machines interact through the rotating magnetic field generated by the stator and the rotor. The key parameter is slip, which is the difference between synchronous speed and rotor speed relative to synchronous speed. Slip is...