Related Experiment Video
Updated: May 3, 2026

Echocardiographic Evaluation of Atrial Communications before Transcatheter Closure
Published on: February 8, 2022
Coronary computed tomography angiography-based tricuspid annular plane systolic excursion: correlation with 2D
Jaspreet Singh1, Mark Borgstrom, Aiden Abidov
1Division of Cardiology, The University of Arizona College of Medicine, Tucson, Arizona.
Background:
Right heart evaluation on coronary computed tomography angiography (CCTA) is underutilized due to nonopacification of the right heart chambers and poor endocardial resolution. We analyzed feasibility and reproducibility of right heart functional analysis by measuring CCTA-based tricuspid annular plane systolic excursion (CT-TAPSE) on ECG-gated CCTA and correlated the results with 2D transthoracic echocardiography (TTE)-derived TAPSE (Echo-TAPSE).
Methods:
CT-TAPSE was measured on a total population of 41 patients who had CCTA and TTE performed within 6 months of each other. Two independent CCTA readers performed analysis on reformatted four-chamber view. Intra- and inter-observer variability analysis was performed on 16 randomly selected patients. Correlative (Spearman's R) and Bland-Altman analysis was used to assess the level of agreement between the 2 methods and to compare CT-TAPSE with Echo-TAPSE.
Results:
CT-TAPSE measured by Readers 1 and 2 on 16 randomly selected patients, demonstrated excellent intra-observer and inter-observer agreement, with very close correlation (R > 0.80 and 2-tailed P-value of <0.001). When tested in the entire study population of 41 patients, CT-TAPSE correlated closely with Echo-TAPSE (R = 0.738, P < 0.001). Bland-Altman analysis indicated that the 2 methods provided similar measures as majority of values lay within the 95% confidence limits. Based on abnormal Echo-TAPSE cutoff value of <16 mm, CT-TAPSE identified impaired right ventricle (RV) function with sensitivity of 82% and specificity of 93%, respectively.
Conclusion:
We demonstrated feasibility and reproducibility of assessing TAPSE on coronary CTA. RV functional analysis utilizing CT-TAPSE is simple and reproducible methodology, and is in close agreement with Echo-TAPSE.
Related Concept Videos
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for...
Acute Coronary Syndrome III: Diagnostic Studies
Imaging Studies for Cardiovascular System I:Echocardiography
Indications: Echocardiography is utilized to diagnose heart failure, valve disorders, and myocardial infarction. It also assesses cardiac structures' size, shape, and motion,...
Aortic Regurgitation II: Clinical Features and Diagnostic Tests
Correlation between ECG and Cardiac Cycle
A cardiac action potential originates in the SA node and spreads throughout the atria and the AV node in approximately 0.03 seconds. This results in the P wave in an ECG and triggers atrial contraction. The action potential is then briefly slowed at the AV node, allowing the atria to contract and fill the ventricles with blood before...
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT