Chromatographic Fingerprinting by Template Matching for Data Collected by Comprehensive Two-Dimensional Gas Chromatography
Published on: September 2, 2020
On the use of quadrupole mass spectrometric detection for flow modulated comprehensive two-dimensional gas
Roman Gorovenko1, Ján Krupčík1, Ivan Špánik1
1Institute of Analytical Chemistry, Slovak University of Technology, Bratislava, Slovakia.
Abstract:
Flow modulated comprehensive two-dimensional gas chromatography with simultaneous flame ionization detection (FM GC×GC-FID) and quadrupole mass spectrometric detection (FM GC×GC-qMSD) was applied to the analysis of a quantitative reference standard sample covering the C5-C14 hydrocarbon range and a kerosene sample. This study reports the influence of the data acquisition frequency (DAF) of the qMSD on the qualitative and quantitative data. The DAF was varied between 5.27 and 25.45Hz. In GC×GC-qMSD, the characterization of peaks is getting worse with decreasing qMSD frequencies which deteriorate the quality of the 2D contour plots of the separations. It is, however, demonstrated that the improved characterization of the peaks at high qMSD frequencies is combined with loss in sensitivity and in spectral quality. Dependences of a (2)D hydrocarbon peak area (∑Ai of all corresponding (2)D peaks) on the DAFs show negative slopes which testify the conclusion that the sensitivity of GC×GC-qMSD determinations decreases with the increase of DAF. Consequently, the limits of detection (LOD) and quantification (LOQ) increase with the increase of DAF. Moreover, quality criteria on recorded spectral data also indicate that the lower the DAF is, the higher is the spectral quality.
More Related Videos
07:57Quantitative Detection of Trace Explosive Vapors by Programmed Temperature Desorption Gas Chromatography-Electron Capture Detector
Published on: July 25, 2014
11:44Qualitative Characterization of the Aqueous Fraction from Hydrothermal Liquefaction of Algae Using 2D Gas Chromatography with Time-of-flight Mass Spectrometry
Published on: March 6, 2016
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Gas Chromatography: Types of Detectors-II
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Mass Analyzers: Common Types