The role of stability measurements of the Baha® system in children
Related Experiment Video
Updated: May 3, 2026

Quantitative Static and Dynamic Assessment of Balance Control in Stroke Patients
Published on: May 17, 2020
M Felton1, P Hill-Feltham2, I A Bruce3
1Paediatric ENT Department, Royal Manchester Children's Hospital, Central Manchester University Hospitals NHS Foundation Trust, Manchester Academic Health Science Centre, Manchester M13 9WL, UK.
Objective:
Percutaneous bone conduction hearing aids are an established treatment for selected children unable to use conventional hearing aids. Currently in children, loading the implant is delayed for 3-6 months following fixture placement, due to concerns regarding bone quality, bone thickness and subsequent implant stability. Traditionally, such concerns led to children undergoing 2-stage Baha(®) surgery, with a second operation to attach the abutment after 3-6 months. Bone conduction implant stability can be objectively measured using resonance-frequency analysis (RFA) to generate Implant Stability Quotients (ISQs). We aimed to assess implant stability in children undergoing 1-stage surgery using RFA measurements and investigate the possible implications for earlier loading following surgery.
Methods:
We report a case series of consecutive children undergoing Baha(®) at our tertiary paediatric hospital. The interval to implant loading remained 3-6 months for the duration of this study. RFA measurements were taken peri-operatively, 1 week post-surgery, within 3 months of surgery and then subsequently at follow up appointments. RFA measurements were also measured at loading of the hearing processor and at follow up appointments after loading.
Results:
Nine children received 10 Cochlear™ Baha(®) BI300 implants (8 unilateral and 1 bilateral) with a mean age of 9 years 4 months (4 years 9 months to 13 years 5 months). The mean time to loading of the hearing processor was 3.3 months (3 to 5 months, n=9) and mean follow up was 9 months (12 weeks to 23 months). Eight children had ISQs that were potentially sufficient to have loaded the implant earlier than 3 months. Implant stability was maintained after loading with the hearing processor.
Conclusion:
This study supports the potential use of RFA measurements to either, guide implant loading following 1-stage surgery in children, or to enable a larger prospective study of early loading (4-6 weeks) in children.
More Related Videos
08:22Measuring Cardiac Autonomic Nervous System ANS Activity in Toddlers - Resting and Developmental Challenges
Published on: February 25, 2016
13:08Measurement of Fronto-limbic Activity Using an Emotional Oddball Task in Children with Familial High Risk for Schizophrenia
Published on: December 2, 2015
Related Concept Videos
BIBO stability of continuous and discrete -time systems
To determine the BIBO stability, the convolution integral is utilized when a bounded continuous-time input is applied to a Linear Time-Invariant (LTI) system....
Stability
The stability of an LTI system is determined by the roots of its characteristic equation, known as poles. A system is stable if it produces a bounded...
Pole and System Stability
Simple poles are unique roots of the denominator polynomial. Each simple pole corresponds to a distinct solution to the system's characteristic equation, typically resulting in exponential decay terms in the system's...
Stability of Equilibrium Configuration: Problem Solving
Problem-solving in the context of the stability of equilibrium configuration...