Related Experiment Video
Updated: May 3, 2026

Sampling and Analysis of Animal Scent Signals
Published on: February 13, 2021
Analysis of 7 synthetic musks in cream by supported liquid extraction and solid phase extraction followed by GC-MS/MS
Haifeng Dong1, Hua Tang2, Dazhou Chen2
1State Key Laboratory of Chemical Resource Engineering, Beijing University of Chemical Technology, Beijing 100029, China.
Abstract:
A new method for the simultaneous determination of 7 synthetic musks (musk amberette, musk tibetene, musk moskene, musk ketone, musk xylene, phantolide, and tonalide) in cream by means of supporting liquid extraction (SLE) coupled with LC-Alumina-N SPE, then followed by GC-MS/MS has been established. In this study, 7 synthetic musks are extracted and pre-purified by a mixture solution of water and isopropanol from cream, and separated and purified by tandem columns containing SLE column and LC-Alumina-N SPE column, which were seldom reported before. Ultrasonic and mechanical shaking were applied to improve the extraction efficiency. Different experiment conditions, such as the type of extraction solution, extraction time of ultrasonic and mechanical shaking, the type of SLE and SPE column, and matrix effects were optimized and the recoveries of 7 synthetic musks for each part were above 86.61%. In addition, the use of isotope internal standards was systemically discussed. The method showed satisfactory linearity over the range assayed (5-1000 ng g(-1)), and the limits of detections (LODs) ranged from 0.15 to 4.86 ng g(-1), and the limits of quantifications (LOQs) were ranging from 0.49 to 16.21 ng g(-1). The recoveries using this method at three spiked concentration levels (10, 100, and 1000 ng g(-1)) range from 85.6% to 109%. The relative standard deviation was lower than 9.8% in all case. The proposed analytical method has been successfully applied for the analysis of 7 synthetic musks in commercial cream.
More Related Videos
09:38Single-throughput Complementary High-resolution Analytical Techniques for Characterizing Complex Natural Organic Matter Mixtures
Published on: January 7, 2019
11:59Extraction and Detection of Geosmin and 2-Methylisoborneol in Water and Fish using High-Capacity Sorptive Extraction Probes and GC-MS
Published on: July 3, 2025
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...