Related Experiment Video
Updated: May 3, 2026

Using Extraordinary Optical Transmission to Quantify Cardiac Biomarkers in Human Serum
Published on: December 13, 2017
Optimal cut-off value for cardiac troponin I in ruling out Type 5 myocardial infarction
Peter Hartmund Jørgensen1, Mads Nybo, Marianne Kjær Jensen
1Department of Cardiology, Odense University Hospital, Odense C, Denmark.
Objectives:
The clinical classification of myocardial infarction (MI) into five types was introduced in 2007 as a component of the universal definition. A Type 5 MI was defined as a MI related to coronary artery bypass surgery. In a setting of patients undergoing elective coronary artery bypass grafting, we set out (i) to describe the pattern of multiple serial cardiac troponin I (cTnI) measurements within 72 h postoperatively and (ii) to determine the optimal cardiac troponin I cut-off value in ruling in or ruling out a Type 5 MI.
Methods:
In 2011-2012, patients with two- and three-vessel disease scheduled for elective on-pump coronary artery bypass grafting were considered. Samples for cTnI were drawn before and 0, 2, 4, 6, 12, 24, 48 and 72 h after surgery. Analysis for cardiac troponin I was performed by use of the Abbott Architect c16000 system with an upper reference limit (URL) of 30 ng/l. The diagnosis of a Type 5 MI was prospectively made by a consultant cardiologist and was based on clinical, electrocardiographic and imaging data together with routine sampling and measurements of cTnI, but without knowledge of the results of serial study cTnI measurements.
Results:
Of the 141 eligible patients, 99 (70%) qualified for final enrollment. In 8 patients (8%), the clinical diagnosis of a Type 5 MI was made. Patients without Type 5 MI (n = 91) had a median cTnI peak value of 7675 ng/l compared with 20 500 ng/l in Type 5 MI patients (P = 0.01). By use of receiver operating characteristic curves, optimal cut-off values for identifying Type 5 MI were defined as 7970 ng/l (corresponding to 266 times the URL) 12 h postoperatively and 9950 ng/l (corresponding to 331 times the URL) 24 h postoperatively. These cut-off values resulted in negative predictive values of 0.99 (12 h) and 0.99 (24 h). Positive predictive values were 0.23 (12 h) and 0.35 (24 h).
Conclusions:
In clinically stable patients undergoing elective coronary artery bypass grafting, measurements of cTnI are useful in ruling out a Type 5 MI.
More Related Videos
07:40Impact of High-intensity Interval Exercise and Moderate-Intensity Continuous Exercise on the Cardiac Troponin T Level at an Early Stage of Training
Published on: October 10, 2019
11:17A Microscopic 2,3,5-Triphenyltetrazolium Chloride Assay for Accurate and Reliable Analysis of Myocardial Injury
Published on: November 28, 2025
Related Concept Videos
Blood Studies for Cardiovascular System I: Cardiac Biomarkers
The essential diagnostic tools for detecting myocardial necrosis and monitoring individuals suspected of having acute coronary syndrome (ACS) include:
Troponins
Troponins, particularly cardiac troponins I and T, are the most precise and sensitive markers of myocardial injury. They are detectable within 4-6 hours of myocardial injury and remain...
Acute Coronary Syndrome III: Diagnostic Studies
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Myocarditis II: Clinical Features and Diagnostic Tests
Acute Coronary Syndrome I: Introduction
Blood Studies for Cardiovascular System II: CRP, Hcy, and Cardiac Natriuretic Peptide Markers
These markers indicate stress or strain on the heart muscle:
Natriuretic Peptides (BNP)
Cardiac myocytes produce these hormones in response to ventricular stretching...