Investigation of the application of phase contrast imaging using a point X-ray source to industrial non-destructive
1Nikon Metrology UK Ltd, Tring Business Centre, Icknield Way, Tring, Herts HP23 4JX, UK.
Abstract:
X-Tek Systems, a division of Nikon Metrology UK, designs, develops and manufactures microfocus X-ray radiography and computed tomography systems for industrial non-destructive testing. The range of X-ray acceleration voltages of its current standard products is 130-450 kV. It is widely known that X-ray images can be created using phase contrast formed by the natural propagation of X-rays. Simulation of the natural propagation of X-rays through a cylindrical test sample predicted a small contrast peak at the boundary between the cylinder material and air. Comparison data were obtained using an X-ray source with acceleration voltage above 100 kV. The simulation results correlated well with the experimental data. A further practical example (a 'magic mirror' amulet from an old Japanese shrine) is introduced and discussed. In this specimen, we detected intensity variation including the effect of phase contrast in the operating region above 100 kV. In summary, natural propagation phase contrast was observed in radiographic images from a standard point X-ray source with acceleration voltages exceeding 100 kV.
Related Concept Videos
X-ray Imaging
X-ray Diffraction of Biological Samples
According to Bragg's law, when X-rays strike the sample positioned on a stage, the rays are scattered by the electron clouds around the sample atoms. The X-ray diffraction or scattering is caused by constructive interference of the X-ray waves that reflect off the internal...
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
Radiological Investigation I: X-ray and CT
X-ray Crystallography
Diffraction
Diffraction is the change in the direction of travel experienced by an electromagnetic wave when it encounters a physical barrier whose dimensions are comparable to those of the wavelength of the light. X-rays are electromagnetic radiation with wavelengths about as long as the distance between neighboring...