Diagnostic accuracy of computed tomography pulmonary angiography with reduced radiation and contrast material dose: a
Zsolt Szucs-Farkas1, Andreas Christe, Boglarka Megyeri
1From the *University Institute of Diagnostic, Interventional and Paediatric Radiology, Inselspital, University Hospital Bern, Berne; †Institute of Radiology, Hospital Centre of Biel, Biel/Bienne, Switzerland; ‡Department of Anaesthesiology and Intensive Care, University of Debrecen, Health and Medical Science Centre, Debrecen, Hungary; §Department of Emergency Medicine, Inselspital, University Hospital Bern, Berne; ∥Department of Emergency Medicine, University Hospital Basel, Basel, Switzerland; ¶Department of Medicine, University of Debrecen, Health and Medical Science Centre, Debrecen, Hungary; and #Department of Radiology, University Hospital Basel, Basel, Switzerland.
Objective:
The objective of the study was to test the diagnostic performance of low-dose computed tomography pulmonary angiography (CTPA) at peak tube voltage of 80 kVp with both reduced radiation and reduced contrast material (CM) dose.
Materials And Methods:
In this single-center, single-blinded prospective randomized trial, 501 patients with body weights of less than 100 kg with suspected acute pulmonary embolism (PE) were assigned to normal-dose CTPA (100-kVp tube energy and 100-mL CM, 255 patients) and low-dose CTPA (80-kVp tube energy and 75-mL CM, 246 patients). Primary end points were evidence of PE in CTPA and accuracy of CTPA on a composite reference standard. Results were compared by calculating the odds ratio with the 95% confidence interval.
Results:
The reference diagnosis was equivocal in 20 of the 501 patients. Diagnosis of CTPA was correct in 240 patients and incorrect in 5 in the normal-dose group. Computed tomography pulmonary angiography was correct in 230 patients and incorrect in 6 in the low-dose group (odds ratio, 1.25; 95% confidence interval, 0.38-4.16; P = 0.77). Sensitivity was 96.9% and 100% and specificity was 98.1% and 97.1% in the normal-dose and low-dose groups, respectively. No PE or PE-related death occurred during the 90-day follow-up. The size-specific dose estimates were 30% lower at 80 kVp (4.8 ± 1.0 mGy) compared with that at 100 kVp (6.8 ± 1.2 mGy; P < 0.001).
Conclusions:
The accuracy of low-dose CTPA at 80 kVp with a 30% reduced radiation dose and a 25% lower CM volume is not significantly different from that of normal-dose CTPA at 100 kVp in detecting acute PE in patients weighing less than 100 kg.
More Related Videos
06:02Anatomical Reconstructions of the Human Cardiac Venous System using Contrast-computed Tomography of Perfusion-fixed Specimens
Published on: April 18, 2013
09:49Dual-phase Cone-beam Computed Tomography to See, Reach, and Treat Hepatocellular Carcinoma during Drug-eluting Beads Transarterial Chemo-embolization
Published on: December 2, 2013
Related Concept Videos
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies for Cardiovascular System V: CT
Imaging Studies III: Computed Tomography
Pulmonary Embolism II: Diagnostic Studies and Interprofessional Care
Radiological Investigation I: X-ray and CT