Related Experiment Video
Updated: May 3, 2026

Endotracheal Intubation via Tracheotomy and Subsequent Thoracotomy in Rats for Non-Survival Applications
Published on: March 15, 2024
Utilization of a standardized tracheostomy capping and decannulation protocol to improve patient safety
Vinciya Pandian1, Christina R Miller, Adam J Schiavi
1Percutaneous Tracheostomy Service, The Johns Hopkins Hospital, Baltimore, Maryland, U.S.A.
Objectives/Hypothesis:
To develop and assess the feasibility of a new standardized protocol to guide tracheostomy decannulation.
Study Design:
Descriptive review of quality improvement project.
Methods:
A quality improvement project was conducted in the inpatient setting of a tertiary urban academic hospital. Adult patients who had received a tracheostomy and for whom the indication for tracheostomy had resolved were included. A multidisciplinary task force reviewed input from clinicians caring for tracheostomy patients and developed a protocol for screening, capping, and decannulation. The primary outcome measured was successful decannulation.
Results:
Fifty-seven patients were screened for a capping trial over a 12-month period; 54 were capped. Six patients were lost to follow-up. Fifty patients passed the capping trial, and all 50 were decannulated successfully. When decannulation was pursued in one patient who had twice failed the screening criteria and subsequent capping trials, the patient failed decannulation and ultimately required reintubation for the management of secretions. The screening tool had high sensitivity (90%) and positive predictive value (100%) for successful decannulation. Additionally, the number of reported patient safety concerns decreased from seven in the 6 months preceding implementation of the program to one report in the 6 months after implementation.
Conclusion:
The new tracheostomy capping and decannulation protocol assisted in predicting both successful and failed decannulation. Although several patients failed certain capping criteria initially, the protocol stipulated modifications of care that enabled successful decannulation. The screening tool had high sensitivity and promoted communication, standardization of practice, and patient safety.
Related Concept Videos
Tracheostomy Decannulation
Description of the Procedure
Decannulation refers to the permanent removal of the tracheostomy tube, signaling the resolution of the condition that initially necessitated the tracheostomy. The process requires a well-coordinated interplay between...
Tracheostomy Care I: Pre-procedural Steps
Required Equipment
The equipment necessary for tracheostomy care includes:
Tracheostomy Care II: Procedure
Step 1: Perform hand hygiene, and put on personal protective equipment: gown, gloves, mask...
Tracheostomy: Procedure and Tubes
Tracheostomy tubes can be made of semiflexible plastic (polyurethane or silicone), rigid plastic, or metal, and they come in...
Tracheostomy Suctioning I: Pre-Procedural Steps
Equipment Required
First, gather all necessary equipment: a sterile suction catheter, a sterile disposable container, sterile gloves, a towel or...
Tracheostomy Suctioning II: Procedure

