Related Experiment Video
Updated: May 3, 2026

Rapid and Specific Detection of Acinetobacter baumannii Infections Using a Recombinase Polymerase Amplification/Cas12a-based System
Published on: April 25, 2025
Comparison of conventional PCR, multiplex PCR, and loop-mediated isothermal amplification assays for rapid detection
Xiaoyu Wang1, Dong Joo Seo, Min Hwa Lee
1Department of Food and Nutrition, School of Food Science and Technology, Chung-Ang University, Ansung-Si, Gyeonggi-Do, South Korea.
Abstract:
This study aimed to develop a loop-mediated isothermal amplification (LAMP) method for the rapid detection of Arcobacter species. Specific primers targeting the 23S ribosomal RNA gene were used to detect Arcobacter butzleri, Arcobacter cryaerophilus, and Arcobacter skirrowii. The specificity of the LAMP primer set was assessed using DNA samples from a panel of Arcobacter and Campylobacter species, and the sensitivity was determined using serial dilutions of Arcobacter species cultures. LAMP showed a 10- to 1,000-fold-higher sensitivity than multiplex PCR, with a detection limit of 2 to 20 CFU per reaction in vitro. Whereas multiplex PCR showed cross-reactivity with Campylobacter species, the LAMP method developed in this study was more sensitive and reliable than conventional PCR or multiplex PCR for the detection of Arcobacter species.