1School of Electrical Engineering, Korea University, Anam-dong, Seongbuk-gu, Seoul, 136-713, Republic of Korea, chuabeelee@gmail.com.
Abstract:
We demonstrated in vitro sterilization of Escherichia coli O157:H7 bacteria on agar by a pin-between-planes micro corona ionizer. The gap between the pin and the grid was ~1.1 mm, the length of the grid was ~2.1 mm and the height was ~1.0 mm. The effective pin radius and discharge length were both approximated to be 200 μm. Ozone generation rates of ~2.3 × 10(-3) mg/s, ~2.7 × 10(-3) mg/s and ~3.5 × 10(-3) mg/s at 1,500 V were calculated for relative humidity (RH) of 35 %, 25 % and 10 % respectively. Analytical ozone generation rate increases as RH decreases and it is consistent with experimental observations. Using target and control petri dishes with E. coli plated agar, the sterilization capability of the micro corona ionizer at 37 °C for 24 h was evaluated. A ~60 % reduction in bacterial colony was shown with plate counting and its kill radius could be tuned from ~ 20 mm to ~5 mm by reducing the duty cycle from 100 % to 50 % with 30 min pulse width. The results suggested that the micro corona ionizer might be suitable as a tunable ozone source in wound dressing for chronic wound management.
Related Concept Videos
Methods of Sterilization II: Chemical Methods
Using chemical sterilization rather than heat to clean out equipment is recommended. It eradicates and removes all bacteria,...
Methods of Sterilization I: Physical Methods
Steam sterilization uses non-toxic, low-cost moist heat in the form of saturated steam under pressure, which is fast, microbicidal, and sporicidal, and quickly warms and penetrates fabrics. Autoclaves, or steam sterilizers, expose each item to direct steam contact for a predetermined time at the necessary...
Cleaning, Sterilization, and Disinfection
Cleaning
The cleaning process usually involves using water with detergents or enzymatic cleaner and removing foreign material from objects and surfaces, including organic material such as body fluids or inorganic material like soil. Cleaning is performed before high-level disinfection and sterilization because foreign materials on the cover of the devices interfere with process...
Physical Methods for Controlling Microbial Growth: Radiation and Filtration
Chemical Agents for Microbial Control
Physical Methods for Controlling Microbial Growth: Temperature