Related Experiment Video
Updated: May 3, 2026

Measurement of Particle Size Distribution in Turbid Solutions by Dynamic Light Scattering Microscopy
Published on: January 9, 2017
Quorum vs. diffusion sensing: a quantitative analysis of the relevance of absorbing or reflecting boundaries
Antonio Trovato1, Flavio Seno, Marina Zanardo
1CNISM and Department of Physics and Astronomy "Galileo Galilei", Università di Padova, Padova, Italy; Istituto Nazionale Fisica Nucleare (INFN), Padova, Italy.
Abstract:
The consequences of the boundary conditions (signal reflecting vs. signal adsorbing) on bacterial intercellular communication were addressed by a combined physics and microbiology approach. A predictive biophysical model was devised that considered system size, diffusion from given points, signal molecule decay and boundary properties. The theoretical predictions were tested with two experimental agarose-gel-based set-ups for reflecting or absorbing boundaries. N-acyl homoserine lactone (AHL) concentration profiles were measured using the Agrobacterium tumefaciens NTL4 bioassay and found to agree with model predictions. The half-life of AHL was estimated to be 7 days. The absorbing vs. reflecting nature of the boundaries drastically changed AHL concentration profiles. The effect of a single nonreflecting boundary side was equivalent to a 100-fold lower cell concentration. Results suggest that the kinetics of signal accumulation vs. signal removal and their threshold-mediated phenotypic consequences are directly linked to the properties of biofilm boundaries, stressing the relevance of the diffusion sensing component in bacterial communication.
More Related Videos
12:06Molecular Diffusion in Plasma Membranes of Primary Lymphocytes Measured by Fluorescence Correlation Spectroscopy
Published on: February 1, 2017
05:56Spot Variation Fluorescence Correlation Spectroscopy for Analysis of Molecular Diffusion at the Plasma Membrane of Living Cells
Published on: November 12, 2020
Related Concept Videos
Gene Regulation in Microbial Communities: Quorum Sensing
Spectrophotometry: Introduction
The essential components of a spectrophotometer include a source of electromagnetic radiation, a slot for placing a material to be analyzed, and a...
Difference from Background: Limit of Detection
The LOD indicates the presence or absence...
Theories of Dissolution: Diffusion Layer Model
This process starts with a thin layer, saturated with the drug, forming at the interface between the solid and liquid. The solute then diffuses from this layer into the main solution. The Noyes-Whitney equation suggests that the rate of dissolution relies on the diffusion...
Bacterial Signaling