Myofibroblasts: the ideal target to prevent arteriovenous fistula failure?

Juan Camilo Duque1, Roberto I Vazquez-Padron1

  • 1DeWitt Daughtry Family Department of Surgery, Leonard M. Miller School of Medicine, University of Miami, Miami, Florida, USA.

Kidney International
|February 4, 2014
PubMed

Related Concept Videos

A Modified Technique for Arteriovenous Fistula Construction in Rabbits05:00

A Modified Technique for Arteriovenous Fistula Construction in Rabbits

The present protocol proposes the creation of an arteriovenous fistula in rabbits using a modified no-touch technique. The technique involves the side-to-side anastomosis of the common carotid artery and external jugular vein without the dissection of the perivenous tissues or cutting off the...
1.8K
Creating Radio-cephalic Arteriovenous Fistula in the Forearm with a Modified No-Touch Technique07:30

Creating Radio-cephalic Arteriovenous Fistula in the Forearm with a Modified No-Touch Technique

We present a modified no-touch technique (MNTT) to create a radio-cephalic arteriovenous fistula (RC-AVF) in which the venous and arterial wall avoid devascularization and the radial artery does not...
8.9K
Intraluminal Drug Delivery to the Mouse Arteriovenous Fistula Endothelium05:53

Intraluminal Drug Delivery to the Mouse Arteriovenous Fistula Endothelium

After puncturing the aorta through the inferior vena cava (IVC) to create an aorto-caval fistula in the mouse, solution containing a drug is infused into the IVC via the same needle, followed by incubation. This method enables more robust drug delivery to the venous endothelium compared to the external...
9.8K
A Novel Murine Model of Arteriovenous Fistula Failure: The Surgical Procedure in Detail10:10

A Novel Murine Model of Arteriovenous Fistula Failure: The Surgical Procedure in Detail

Here we present a murine model of arteriovenous fistula (AVF) failure in which a clinically relevant anastomotic configuration is incorporated. This model can be used to study the pathophysiology and to test possible therapeutic...
13.8K
Technical Aspects of the Mouse Aortocaval Fistula06:12

Technical Aspects of the Mouse Aortocaval Fistula

The goal is to produce an arteriovenous fistula that is simple and reproducible. This method does not use sutures or glue adhesive. Therefore the samples can be used with the least amount of foreign materials for...
17.4K
Ideal Solutions02:24

Ideal Solutions

According to Raoult’s law, the partial vapor pressure of a solvent in a solution is equal or identical to the vapor pressure of the pure solvent multiplied by its mole fraction in the solution. However, Raoult's Law is only valid for ideal solutions. For a solution to be ideal, the solvent-solute interaction must be just as strong as a solvent-solvent or solute-solute interaction. This suggests that both the solute and the solvent would use the same amount of energy to escape to the...
22.2K