Related Experiment Video
Updated: May 3, 2026

Alternative In Vitro Methods for the Determination of Viral Capsid Structural Integrity
Published on: November 16, 2017
Inactivation of human norovirus in contaminated oysters and clams by high hydrostatic pressure
Mu Ye1, Xinhui Li, David H Kingsley
1Department of Animal and Food Sciences, University of Delaware, Newark, Delaware, USA.
Abstract:
Human norovirus (NoV) is the most frequent causative agent of food-borne disease associated with shellfish consumption. In this study, the effect of high hydrostatic pressure (HHP) on inactivation of NoV was determined. Genogroup I.1 (GI.1) or genogroup II.4 (GII.4) NoV was inoculated into oyster homogenates and treated at 300 to 600 MPa at 25, 6, and 1°C for 5 min. After HHP, samples were treated with RNase and viral particles were extracted with porcine gastric mucin (PGM)-conjugated magnetic beads (PGM-MBs). Viral RNA was then quantified by real-time reverse transcription (RT)-PCR. Since PGM contains histo-blood group-like antigens, which can act as receptors for NoV, deficiency for binding to PGM is an indication of loss of infectivity of NoV. After binding to PGM-MBs, RT-PCR-detectable NoV RNA in oysters was reduced by 0.4 to >4 log10 by HHP at 300 to 600 MPa. The GI.1 NoV was more resistant to HHP than the GII.4 NoV (P < 0.05). HHP at lower temperatures significantly enhanced the inactivation of NoV in oysters (P < 0.05). Pressure treatment was also conducted for clam homogenates. Treatment at 450 MPa at 1°C achieved a >4 log10 reduction of GI.1 NoV in both oyster and clam homogenates. It is therefore concluded that HHP could be applied as a potential intervention for inactivating NoV in raw shellfish. The method of pretreatment of samples with RNase, extraction of viral particles using PGM-MB binding, and quantification of viral RNA using RT-PCR can be explored as a practical means of distinguishing between infectious and noninfectious NoV.
Related Concept Videos
Physical Methods for Controlling Microbial Growth: Radiation and Filtration
Methods of Sterilization II: Chemical Methods
Using chemical sterilization rather than heat to clean out equipment is recommended. It eradicates and removes all bacteria,...
Osmotic Pressure
Methods of Sterilization I: Physical Methods
Steam sterilization uses non-toxic, low-cost moist heat in the form of saturated steam under pressure, which is fast, microbicidal, and sporicidal, and quickly warms and penetrates fabrics. Autoclaves, or steam sterilizers, expose each item to direct steam contact for a predetermined time at the necessary...

