The characteristics of Audioscan and DPOAE measures in tinnitus patients with normal hearing thresholds
F Zhao1, S D G Stephens, W S Ishak
1* Centre for Hearing and Balance Studies, University of Bristol , England , UK.
Objectives:
To investigate auditory dysfunction in patients with tinnitus and normal hearing thresholds using two sensitive audiological measures.
Design:
The study was designed to investigate the characteristics of Audioscan and DPOAE tests in tinnitus patients with normal hearing thresholds. Audioscan and DPOAE notches were analysed and compared. All tests were performed in a sound-treated chamber or in a sound-treated room.
Study Sample:
Forty-five tinnitus patients with normal hearing thresholds were examined following a written clinical protocol.
Results:
The averaged hearing levels obtained from tinnitus participants were significantly worse at high frequencies than those derived from the normative data. There was a significantly higher prevalence of Audioscan and DPOAE notches, whose central frequencies matched tinnitus frequencies in the mid-frequency regions, but not in the low- and high-frequency regions. A significant correlation was found between the centre frequencies of the Audioscan notches and the DPOAE notches from 500 to 4000 Hz.
Conclusion:
Tinnitus in different frequency regions may be associated with different underlying mechanisms of tinnitus generation. Some negative results on the Audioscan and DPOAE notches matching tinnitus pitches may be due to a limited set of discrete frequencies used for the tinnitus pitch matching test.
Related Concept Videos
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessing Body Temperature - Tympanic membrane
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...