Electronic implementation of a novel surveillance paradigm for ventilator-associated events. Feasibility and
Peter M C Klein Klouwenberg1, Maaike S M van Mourik, David S Y Ong
11 Department of Medical Microbiology.
Rationale:
Accurate surveillance of ventilator-associated pneumonia (VAP) is hampered by subjective diagnostic criteria. A novel surveillance paradigm for ventilator-associated events (VAEs) was introduced.
Objectives:
To determine the validity of surveillance using the new VAE algorithm.
Methods:
Prospective cohort study in two Dutch academic medical centers (2011-2012). VAE surveillance was electronically implemented and included assessment of (infection-related) ventilator-associated conditions (VAC, IVAC) and VAP. Concordance with ongoing prospective VAP surveillance was assessed, along with clinical diagnoses underlying VAEs and associated mortality of all conditions. Consequences of minor differences in electronic VAE implementation were evaluated.
Measurements And Main Results:
The study included 2,080 patients with 2,296 admissions. Incidences of VAC, IVAC, VAE-VAP, and VAP according to prospective surveillance were 10.0, 4.2, 3.2, and 8.0 per 1000 ventilation days, respectively. The VAE algorithm detected at most 32% of the patients with VAP identified by prospective surveillance. VAC signals were most often caused by volume overload and infections, but not necessarily VAP. Subdistribution hazards for mortality were 3.9 (95% confidence interval, 2.9-5.3) for VAC, 2.5 (1.5-4.1) for IVAC, 2.0 (1.1-3.6) for VAE-VAP, and 7.2 (5.1-10.3) for VAP identified by prospective surveillance. In sensitivity analyses, mortality estimates varied considerably after minor differences in electronic algorithm implementation.
Conclusions:
Concordance between the novel VAE algorithm and VAP was poor. Incidence and associated mortality of VAE were susceptible to small differences in electronic implementation. More studies are needed to characterize the clinical entities underlying VAE and to ensure comparability of rates from different institutions.
Related Concept Videos
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Mechanical Ventilation I: Indication and Settings
Ventilatory Modes
There are three ventilatory modes: full support, partial support, and spontaneous. These are described below.
Full Support Modes
Full support modes include controlled mechanical ventilation, continuous mandatory...
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation...
Assessment of Ventilation II: Respiratory Depth and Rhythm
Respiratory depth measures the volume of air inhaled or exhaled during a breath. It can vary from shallow to deep and typically remains consistent when a person is at rest or asleep. Occasionally, individuals will automatically inhale deeply, known as sighing, which inflates the lungs with more air than normal breathing.
To assess respiratory depth, observe the degree of chest excursion or movement:
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation: