Related Experiment Video
Updated: May 3, 2026

Frequency Mixing Magnetic Detection Scanner for Imaging Magnetic Particles in Planar Samples
Published on: June 9, 2016
Removal of particulate matter emitted from a subway tunnel using magnetic filters
Youn-Suk Son1, Trieu-Vuong Dinh, Sang-Gwi Chung
1Exposure, Epidemiology, and Risk Program, Department of Environmental Health, Harvard School of Public Health , 401 Park Drive, Landmark Center West Room 417, Boston, Massachusetts 02115, United States.
Abstract:
We removed particulate matter (PM) emitted from a subway tunnel using magnetic filters. A magnetic filter system was installed on the top of a ventilation opening. Magnetic field density was increased by increasing the number of permanent magnet layers to determine PM removal characteristics. Moreover, the fan's frequency was adjusted from 30 to 60 Hz to investigate the effect of wind velocity on PM removal efficiency. As a result, PM removal efficiency increased as the number of magnetic filters or fan frequency increased. We obtained maximum removal efficiency of PM10 (52%), PM2.5 (46%), and PM1 (38%) at a 60 Hz fan frequency using double magnetic filters. We also found that the stability of the PM removal efficiency by the double filter (RSD, 3.2-5.8%) was higher than that by a single filter (10.9-24.5%) at all fan operating conditions.