Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Deconvolution01:20

Deconvolution

764
Deconvolution, also known as inverse filtering, is the process of extracting the impulse response from known input and output signals. This technique is vital in scenarios where the system's characteristics are unknown, and they must be inferred from the observable signals.
Deconvolution involves several mathematical techniques to derive the impulse response. One common approach is polynomial division. In this method, the input and output sequences are treated as coefficients of...
764
Calibration Curves: Linear Least Squares01:20

Calibration Curves: Linear Least Squares

4.3K
A calibration curve is a plot of the instrument's response against a series of known concentrations of a substance. This curve is used to set the instrument response levels, using the substance and its concentrations as standards. Alternatively, or additionally, an equation is fitted to the calibration curve plot and subsequently used to calculate the unknown concentrations of other samples reliably.
For data that follow a straight line, the standard method for fitting is the linear...
4.3K
Spherical Coordinates01:23

Spherical Coordinates

12.1K
Spherical coordinate systems are preferred over Cartesian, polar, or cylindrical coordinates for systems with spherical symmetry. For example, to describe the surface of a sphere, Cartesian coordinates require all three coordinates. On the other hand, the spherical coordinate system requires only one parameter: the sphere's radius. As a result, the complicated mathematical calculations become simple. Spherical coordinates are used in science and engineering applications like electric and...
12.1K
Glassware Calibration01:11

Glassware Calibration

2.0K
Accurate calibration of glassware, such as volumetric flasks, pipettes, and burettes, is essential to ensure accurate measurements in the analytical laboratory. Calibration helps maintain consistency across measurements and prevents errors arising from inaccurate volumes.
Volumetric flasks: Volumetric flasks are designed to prepare aqueous solutions of precise volumes accurately with a calibration line on the neck. To calibrate a volumetric flask, it is important to fill it with distilled...
2.0K
Distance Corrections01:15

Distance Corrections

430
To achieve precise distance measurements, especially in surveying and construction, certain corrections must be applied to account for potential sources of error like the standardization errors, temperature variations, and slope adjustments.Standardization error emerges when measurement equipment undergoes changes, such as wear, repairs, or weather impacts. To address this, surveyors compare the equipment’s readings to a standard. This process identifies any deviation that might lead to...
430
Gauss's Law: Spherical Symmetry01:26

Gauss's Law: Spherical Symmetry

7.2K
A charge distribution has spherical symmetry if the density of charge depends only on the distance from a point in space and not on the direction. In other words, if the system is rotated, it doesn't look different. For instance, if a sphere of radius R is uniformly charged with charge density ρ0, then the distribution has spherical symmetry. On the other hand, if a sphere of radius R is charged so that the top half of the sphere has a uniform charge density ρ1 and the bottom half has...
7.2K

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Symptom-based rehabilitation in people with post-COVID-19 condition (RELOAD study): a randomised controlled trial.

BMJ open respiratory research·2026
Same author

Continuation or Withdrawal of Life-sustaining Therapies After Acute Anoxic Events in Childhood and Adolescence : Can Early MRI Predict Particularly Severe Outcomes?

Clinical neuroradiology·2026
Same author

Automated Deep Learning-Based Demyelination Load Segmentation in Metachromatic Leukodystrophy.

Clinical neuroradiology·2026
Same author

RapidParc: A global-context transformer for parallel, accurate, and lesion-robust tractogram parcellation.

Imaging neuroscience (Cambridge, Mass.)·2026
Same author

Diagnostic Clues and Pitfalls in Pontocerebellar Hypoplasia Type 2A.

Pediatric neurology·2026
Same author

Consensus-Based Expert Recommendations for Diagnosis and Clinical Management of Vanishing White Matter.

Neurology·2025
Same journal

LiftReg: Limited Angle 2D/3D Deformable Registration.

Medical image computing and computer-assisted intervention : MICCAI ... International Conference on Medical Image Computing and Computer-Assisted Intervention·2026
Same journal

Inverse Consistency by Construction for Multistep Deep Registration.

Medical image computing and computer-assisted intervention : MICCAI ... International Conference on Medical Image Computing and Computer-Assisted Intervention·2026
Same journal

Can Crowdsourced Annotations Improve AI-based Congestion Scoring For Bedside Lung Ultrasound?

Medical image computing and computer-assisted intervention : MICCAI ... International Conference on Medical Image Computing and Computer-Assisted Intervention·2026
Same journal

Equivariant Filters for Efficient Tracking in 3D Imaging.

Medical image computing and computer-assisted intervention : MICCAI ... International Conference on Medical Image Computing and Computer-Assisted Intervention·2026
Same journal

Lobar Lung Density Embeddings with a Transformer encoder (LobTe) to predict emphysema progression in COPD.

Medical image computing and computer-assisted intervention : MICCAI ... International Conference on Medical Image Computing and Computer-Assisted Intervention·2026
Same journal

uniGradICON: A Foundation Model for Medical Image Registration.

Medical image computing and computer-assisted intervention : MICCAI ... International Conference on Medical Image Computing and Computer-Assisted Intervention·2026
See all related articles

Related Experiment Video

Updated: May 3, 2026

Whole-cell Super-Resolution Imaging via DNA-PAINT on a Spinning Disk Confocal with Optical Photon Reassignment
07:12

Whole-cell Super-Resolution Imaging via DNA-PAINT on a Spinning Disk Confocal with Optical Photon Reassignment

Published on: January 6, 2026

773

Auto-calibrating spherical deconvolution based on ODF sparsity.

Thomas Schultz1, Samuel Groeschel2

  • 1University of Bonn, Germany.

Medical Image Computing and Computer-Assisted Intervention : MICCAI ... International Conference on Medical Image Computing and Computer-Assisted Intervention
|February 8, 2014
PubMed
Summary
This summary is machine-generated.

This study introduces an automated method to determine the fiber response in diffusion MRI, improving accuracy for patient data and enabling quantitative analysis of white matter degeneration. The approach enhances fiber crossing resolution and avoids common deconvolution errors.

More Related Videos

Medical-grade Sterilizable Target for Fluid-immersed Fetoscope Optical Distortion Calibration
07:03

Medical-grade Sterilizable Target for Fluid-immersed Fetoscope Optical Distortion Calibration

Published on: February 23, 2017

7.4K
Bringing the Visible Universe into Focus with Robo-AO
10:35

Bringing the Visible Universe into Focus with Robo-AO

Published on: February 12, 2013

21.4K

Related Experiment Videos

Last Updated: May 3, 2026

Whole-cell Super-Resolution Imaging via DNA-PAINT on a Spinning Disk Confocal with Optical Photon Reassignment
07:12

Whole-cell Super-Resolution Imaging via DNA-PAINT on a Spinning Disk Confocal with Optical Photon Reassignment

Published on: January 6, 2026

773
Medical-grade Sterilizable Target for Fluid-immersed Fetoscope Optical Distortion Calibration
07:03

Medical-grade Sterilizable Target for Fluid-immersed Fetoscope Optical Distortion Calibration

Published on: February 23, 2017

7.4K
Bringing the Visible Universe into Focus with Robo-AO
10:35

Bringing the Visible Universe into Focus with Robo-AO

Published on: February 12, 2013

21.4K

Area of Science:

  • Neuroimaging
  • Diffusion MRI Analysis
  • Computational Neuroscience

Background:

  • Spherical deconvolution is a key technique in diffusion MRI for modeling white matter microstructure.
  • Accurate estimation of the fiber response function is crucial for reliable diffusion MRI signal modeling.
  • Current methods often require manual input for the fiber response, limiting clinical applicability.

Purpose of the Study:

  • To develop and validate a novel, automated calibration procedure for estimating the fiber response function in spherical deconvolution.
  • To improve the analysis of diffusion MRI data, particularly in patient cohorts with white matter degeneration.
  • To enable quantitative analysis of white matter tissue properties derived from diffusion MRI.

Main Methods:

  • Proposed a novel auto-calibration procedure for spherical deconvolution to determine the fiber response.
  • Optimized the method by balancing fitting error and fiber orientation density function (fODF) sparsity.
  • Validated the approach using simulated data and assessed its performance against the FORECAST method.

Main Results:

  • The auto-calibration procedure successfully determined the fiber response without user input.
  • A per-voxel fiber response estimation was achieved, suitable for analyzing patient data with focal white matter degeneration.
  • The method demonstrated improved angular resolution for resolving fiber crossings compared to FORECAST and avoided erroneous fODF peaks.
  • Generated parameter maps indicated potential for quantitative analysis of diffusion properties.

Conclusions:

  • The novel auto-calibration method for spherical deconvolution offers a robust and automated approach to fiber response estimation.
  • This technique enhances the accuracy and applicability of diffusion MRI analysis in clinical settings, especially for studying white matter pathologies.
  • The derived parameters hold promise for quantitative assessment of white matter integrity.