Related Concept Videos

Calibration Curves: Linear Least Squares01:20

Calibration Curves: Linear Least Squares

4.3K
A calibration curve is a plot of the instrument's response against a series of known concentrations of a substance. This curve is used to set the instrument response levels, using the substance and its concentrations as standards. Alternatively, or additionally, an equation is fitted to the calibration curve plot and subsequently used to calculate the unknown concentrations of other samples reliably.
For data that follow a straight line, the standard method for fitting is the linear...
4.3K
Calibration Curves: Correlation Coefficient01:10

Calibration Curves: Correlation Coefficient

5.0K
In a linear calibration curve, there is a value called the calibration coefficient, denoted by 'r,' which measures the strength and the direction of association between two variables. The correlation coefficient value ranges from −1 to +1. A value of +1 indicates a perfect positive linear correlation, −1 denotes a perfect negative correlation, and 0 implies no correlation between the two variables. A positive correlation value establishes that as one variable increases, the...
5.0K
Computed Tomography01:10

Computed Tomography

7.6K
Tomography refers to imaging by sections. Computed tomography (CT) is a non-invasive imaging technique that uses computers to analyze several cross-sectional X-rays to reveal minute details about structures in the body.
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
7.6K
Imaging Studies III: Computed Tomography01:27

Imaging Studies III: Computed Tomography

893
DefinitionComputed Tomography (CT) of the genitourinary (GU) tract is a non-invasive imaging modality that utilizes X-rays and computer processing to generate detailed cross-sectional images of the urinary system, encompassing the kidneys, ureters, bladder, and adjacent structures such as the adrenal glands.PurposeCT scans of the GU tract serve several diagnostic and therapeutic purposes, including:Diagnosis of Urinary Tract Diseases: Detects kidney stones, tumors, cysts, and congenital...
893
Imaging Studies IV: Magnetic Resonance Imaging01:27

Imaging Studies IV: Magnetic Resonance Imaging

427
Introduction:Magnetic Resonance Imaging, or MRI, can include a specialized imaging technique of the urinary system known as Magnetic Resonance Urography (MRU). This radiation-free technique uses strong magnetic fields and radio waves to produce detailed images with the help of a computer. MRU is particularly effective for visualizing fluid-filled structures like the kidneys, ureters, and bladder.Applications of MRI in the Genitourinary SystemKidneys and Ureters: MRI detects tumors, cysts,...
427
Imaging Studies I: CT and MRI01:14

Imaging Studies I: CT and MRI

1.3K
Introduction: MRI and CT scans are crucial advancements in medical imaging techniques, playing a vital role in diagnosing conditions related to the gastrointestinal (GI) system. Each scan serves distinct purposes, targets specific areas, and requires unique nursing duties.
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
1.3K

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

[Kinase-Glo luminescent kinase assay for in vitro determination of PKA activity].

Xi bao yu fen zi mian yi xue za zhi = Chinese journal of cellular and molecular immunology·2012
Same author

Functional characterization of an arrestin gene on insecticide resistance of Culex pipiens pallens.

Parasites & vectors·2012
Same author

MiR-23a inhibits myogenic differentiation through down regulation of fast myosin heavy chain isoforms.

Experimental cell research·2012
Same author

Let-7b inhibits human cancer phenotype by targeting cytochrome P450 epoxygenase 2J2.

PloS one·2012
Same author

Role of IKK/NF-κB signaling in extinction of conditioned place aversion memory in rats.

PloS one·2012
Same author

Inhibition of poly(ADP-ribose) polymerase attenuates acute kidney injury in sodium taurocholate-induced acute pancreatitis in rats.

Pancreas·2012
Same journal

LiftReg: Limited Angle 2D/3D Deformable Registration.

Medical image computing and computer-assisted intervention : MICCAI ... International Conference on Medical Image Computing and Computer-Assisted Intervention·2026
Same journal

Inverse Consistency by Construction for Multistep Deep Registration.

Medical image computing and computer-assisted intervention : MICCAI ... International Conference on Medical Image Computing and Computer-Assisted Intervention·2026
Same journal

Can Crowdsourced Annotations Improve AI-based Congestion Scoring For Bedside Lung Ultrasound?

Medical image computing and computer-assisted intervention : MICCAI ... International Conference on Medical Image Computing and Computer-Assisted Intervention·2026
Same journal

Equivariant Filters for Efficient Tracking in 3D Imaging.

Medical image computing and computer-assisted intervention : MICCAI ... International Conference on Medical Image Computing and Computer-Assisted Intervention·2026
Same journal

Lobar Lung Density Embeddings with a Transformer encoder (LobTe) to predict emphysema progression in COPD.

Medical image computing and computer-assisted intervention : MICCAI ... International Conference on Medical Image Computing and Computer-Assisted Intervention·2026
Same journal

uniGradICON: A Foundation Model for Medical Image Registration.

Medical image computing and computer-assisted intervention : MICCAI ... International Conference on Medical Image Computing and Computer-Assisted Intervention·2026
See all related articles

Related Experiment Video

Updated: May 3, 2026

Four-Dimensional CT Analysis Using Sequential 3D-3D Registration
05:05

Four-Dimensional CT Analysis Using Sequential 3D-3D Registration

Published on: November 23, 2019

7.6K

Calibrationless parallel MRI with joint total variation regularization.

Chen Chen1, Yeqing Li1, Junzhou Huang1

  • 1University of Texas at Arlington, TX 76019, USA.

Medical Image Computing and Computer-Assisted Intervention : MICCAI ... International Conference on Medical Image Computing and Computer-Assisted Intervention
|February 8, 2014
PubMed
Summary
This summary is machine-generated.

This study introduces a new calibrationless method for parallel magnetic resonance imaging (pMRI). The technique improves image quality and offers benefits for clinical MR applications where calibration is challenging.

More Related Videos

Author Spotlight: An Efficient and Robust Software for Automated Fusion of Multiple Preclinical Imaging Modalities
07:13

Author Spotlight: An Efficient and Robust Software for Automated Fusion of Multiple Preclinical Imaging Modalities

Published on: October 27, 2023

2.0K
Multi-modal Pulmonary Imaging: Using Complementary Information from CT and Hyperpolarized 129Xe MRI to Evaluate Lung Structure-Function
02:09

Multi-modal Pulmonary Imaging: Using Complementary Information from CT and Hyperpolarized 129Xe MRI to Evaluate Lung Structure-Function

Published on: April 12, 2024

1.3K

Related Experiment Videos

Last Updated: May 3, 2026

Four-Dimensional CT Analysis Using Sequential 3D-3D Registration
05:05

Four-Dimensional CT Analysis Using Sequential 3D-3D Registration

Published on: November 23, 2019

7.6K
Author Spotlight: An Efficient and Robust Software for Automated Fusion of Multiple Preclinical Imaging Modalities
07:13

Author Spotlight: An Efficient and Robust Software for Automated Fusion of Multiple Preclinical Imaging Modalities

Published on: October 27, 2023

2.0K
Multi-modal Pulmonary Imaging: Using Complementary Information from CT and Hyperpolarized 129Xe MRI to Evaluate Lung Structure-Function
02:09

Multi-modal Pulmonary Imaging: Using Complementary Information from CT and Hyperpolarized 129Xe MRI to Evaluate Lung Structure-Function

Published on: April 12, 2024

1.3K

Area of Science:

  • Medical Imaging
  • Magnetic Resonance Imaging
  • Image Reconstruction

Background:

  • Parallel magnetic resonance imaging (pMRI) is crucial for faster image acquisition.
  • Traditional pMRI methods often require extensive calibration data, limiting their use in certain clinical scenarios.
  • Existing calibrationless pMRI algorithms have shown limitations in performance.

Purpose of the Study:

  • To propose a novel calibrationless method for parallel magnetic resonance imaging (pMRI).
  • To address the limitations of current pMRI techniques, particularly when calibration data is scarce or unavailable.
  • To enhance the performance of pMRI for clinical applications.

Main Methods:

  • Developed a calibrationless pMRI method based on the joint sparsity of aliased image gradients.
  • Formulated the pMRI problem as a joint total variation regularization task.
  • Employed an iterative algorithm for efficient problem solving and utilized a sum of squares approach for field of view reconstruction.

Main Results:

  • The proposed method outperforms state-of-the-art pMRI techniques, even those with sufficient calibration data.
  • Demonstrated significantly better performance compared to existing calibrationless pMRI algorithms.
  • Experimental results on pMRI datasets validate the effectiveness of the new approach.

Conclusions:

  • The developed calibrationless pMRI method offers superior performance and robustness.
  • This technique holds significant potential for clinical MR applications, especially when accurate calibration is limited or impossible.
  • The findings pave the way for wider adoption of pMRI in challenging imaging environments.