Application of Ultrasound and Shear Wave Elastography Imaging in a Rat Model of NAFLD/NASH
Published on: April 20, 2021
Usefulness of evaluating hepatic elasticity using artificial acoustic radiation force ultrasonography before
Atsushi Nanashima1, Ayami Sakamoto, Ichiro Sakamoto
1Department of Surgical Oncology, Nagasaki University Graduate School of Biomedical Sciences, Nagasaki, Japan.
Aim:
To evaluate hepatic fibrosis and tumor diagnosis preoperatively, we investigated the elasticity calculated by the new parameter of ultrasonography, acoustic radiation force impulse (ARFI).
Methods:
We examined ARFI of the non-tumorous right and left lateral liver and in the tumor by push pulse of probe in 95 patients with hepatic malignancies undergoing hepatectomy. Measurement of ARFI as hepatic stiffness was indicated as the Vs (m/s).
Results:
Measuring the Vs in the non-tumor region was achieved in the right liver in 99% and at the left lateral liver in 94%. The Vs in the right liver was significantly lower than in the left lateral liver, and the Vs of the liver tumor was significantly higher than in the non-tumorous liver. The Vs in the right and left lateral liver was correlated with the platelet count, aspartate aminotransferase, fibrotic indices and indocyanine green test. The Vs in the right liver was significantly correlated with the fibrotic marker or index. The Vs of liver cirrhosis and histological stage 4 in the right and left liver was significantly the highest compared to the others. The Vs in the right liver showed a high area under the receiver-operator curve value predicting histological fibrosis. The Vs in the right was significantly correlated with blood loss and postoperative complications, particularly uncontrolled ascites.
Conclusion:
Non-invasive ARFI imaging elastography is useful in evaluating impaired liver function or in the differential diagnosis of liver malignancies, highly hepatic fibrosis and in predicting posthepatectomy morbidity.
More Related Videos
05:56Evaluation of the Feasibility, Safety, and Accuracy of an Intraoperative High-intensity Focused Ultrasound Device for Treating Liver Metastases
Published on: January 9, 2019
06:09Author Spotlight: Advancing Hepatic Fibrosis Diagnosis Using Magnetic Resonance Elastography and AI
Published on: July 21, 2023
Related Concept Videos
Ultrasound II: Endoscopic Ultrasound and FibroScan
Endoscopic Ultrasound (EUS):
Effect of Hepatic Disease on Pharmacokinetics: Pathophysiologic Assessment and Liver Function Test
Assessment of the Abdomen II: Percussion
Percussion
Percussion is an essential...
Ultrasonography
During an ultrasonography procedure, a handheld device called...