Related Experiment Video
Updated: May 3, 2026

Echocardiographic Assessment Using Subxiphoid-Only Examination for Hypotensive Patients
Published on: April 18, 2025
[Clinical evaluation of transthoracic echocardiography predicting fluid responsiveness in septic shock]
Jingyi Wu1, Xia Zhang, Zhen Wang
1Department of Intensive Care Unit, the First Affiliated Hospital of Wannan Medical College, Wuhu Yijishan Hospital, Wuhu 241000, Anhui, China. Corresponding author: Lu Weihua,
Objective:
To evaluate clinical value of transthoracic echocardiography (TTE) predicting fluid responsiveness in patients with severe sepsis or septic shock, the parameters of pulse indicator continuous cardiac output (PiCCO) system was combined.
Methods:
Twenty-eight severe sepsis or septic shock patients with mechanically ventilated in intensive care unit (ICU) of Wannan Medical College Yijishan Hospital were prospectively observed from March 2011 to December 2012. The hemodynamic parameters including stoke volume (SV), cardiac output (CO), cardiac output index (CI) and the distensibility index of the inferior vena cava (dIVC), descending aortic blood flow (ABF) were measured by PiCCO and/or TTE in the supine position. Responders were defined by the appearance of an increase in SV (ΔSV)≥10% after liquid loading. The value of TTE predicting fluid responsiveness was evaluated in severe sepsis or septic shock patients.
Results:
There were a total of 53 times liquid loading test in 28 patients, of which with 30 times was positive. The area under receiver operating characteristic curve (ROC curve, AUC) for dIVC predicting fluid responsiveness was 0.887, the dIVC threshold value of 22.5% had the sensitivity of 83.3% and specificity of 82.6% for prediction of fluid responsiveness. The AUC for ABF predicting fluid responsiveness was 0.794, the ABF variation threshold value of 10.95% had the sensitivity of 86.7% and specificity of 73.9% for prediction of fluid responsiveness. The AUC for SVTTE predicting fluid responsiveness was 0.919, the ΔSV of 12.9% had the sensitivity of 96.7% and specificity of 87.0% for prediction of fluid responsiveness. The SV, CO, CI of TTE were highly correlated with the SV, CO, CI of PiCCO before and after liquid loading (before liquid loading, r=0.901, 0.940, 0.909, after liquid loading r=0.911, 0.951, 0.940, all P=0.000).
Conclusions:
Fluid responsiveness can be predicted using TTE in severe sepsis or septic shock patients.
More Related Videos
Related Concept Videos
Rheumatic Heart Disease II: Clinical Manifestations and Diagnostic Studies
Heart Failure IV: Classification and Diagnostic Evaluation
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for...
Aortic Regurgitation II: Clinical Features and Diagnostic Tests
Imaging Studies for Cardiovascular System I:Echocardiography
Indications: Echocardiography is utilized to diagnose heart failure, valve disorders, and myocardial infarction. It also assesses cardiac structures' size, shape, and motion,...
Acute Coronary Syndrome III: Diagnostic Studies

