Is a palpable pulse always restored during cardiopulmonary resuscitation in a patient with a left ventricular assist
Nicholas A Haglund1, Kelly Schlendorf, Mary Keebler
1Divisions of Cardiovascular Medicine (NAH, KS, MK, CG, DL) and Cardiothoracic Surgery (SM), Vanderbilt University Medical Center, Nashville, Tennessee; and VA-GRECC (Geriatric Research Education Clinical Center) (EWE), VA Tennessee Valley Health Care System, Vanderbilt University Medical Center, Nashville, Tennessee.
Abstract:
End-stage heart failure patients are being supported with continuous flow left ventricular assist devices (CF-LVAD) in increasing numbers. The severe physiologic and pharmacologic derangements associated with end-stage heart failure therapies predispose these patients to delirium. During a delirious episode, a patient may inadvertently disconnect CF-LVAD equipment, which may have dangerous consequences. Unfortunately, it is not yet routine to use readily available clinical monitoring tools to allow early detection of delirium in this high-risk population. The authors present a case of acute hyperactive delirium leading to pump power disconnection and cardiopulmonary arrest occurring 7 days after CF-LVAD implantation. The case highlights the need for delirium awareness in the cardiovascular intensive care unit and the unique challenges associated with resuscitation of CF-LVAD patients. The authors propose that cardiovascular intensive care unit patients undergo at least twice daily delirium monitoring and provide a novel resuscitation algorithm for patients who have CF-LVADs.
More Related Videos
06:10Utilizing Percutaneous Ventricular Assist Devices in Acute Myocardial Infarction Complicated by Cardiogenic Shock
Published on: June 12, 2021
05:18Implantation of Left Ventricular Assist Device (LVAD) in Juvenile Landrace Swine: A LVAD Implantation Model of Pediatric Heart Failure
Published on: January 16, 2026
Related Concept Videos
Cardiopulmonary Resuscitation I: Adult
Cardiopulmonary Resuscitation III: AED Use
Pulse
The pulse serves as a clinical...
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above...
Cardiovascular System Abnormal Findings I: Inspection and Palpation
Abnormal findings observed during an inspection
Cardiomyopathy II: Dilated Cardiomyopathy