Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Depth Perception and Spatial Vision01:15

Depth Perception and Spatial Vision

2.7K
Depth perception is the ability to perceive objects three-dimensionally. It relies on two types of cues: binocular and monocular. Binocular cues depend on the combination of images from both eyes and how the eyes work together. Since the eyes are in slightly different positions, each eye captures a slightly different image. This disparity between images, known as binocular disparity, helps the brain interpret depth. When the brain compares these images, it determines the distance to an object.
2.7K
Super-resolution Fluorescence Microscopy01:37

Super-resolution Fluorescence Microscopy

12.3K
Super-resolution fluorescence microscopy (SRFM) provides a better resolution than conventional fluorescence microscopy by reducing the point spread function (PSF). PSF is the light intensity distribution from a point that causes it to appear blurred. Due to PSF, each fluorescing point appears bigger than its actual size, and it is the PSF interference of nearby fluorophores that causes the blurred image. Various approaches to achieving higher resolution through SRFM have recently been...
12.3K
Phase Contrast and Differential Interference Contrast Microscopy01:26

Phase Contrast and Differential Interference Contrast Microscopy

9.4K
Phase-Contrast Microscopes
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
9.4K

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Pedestrian Collision Detection and Avoidance in Cerebral Visual Impairment During Unrestricted Walking in an Immersive Virtual Reality Environment.

Research square·2026
Same author

A randomized crossover clinical trial of multi-periscopic and Fresnel peripheral prism glasses for hemianopia.

Optometry and vision science : official publication of the American Academy of Optometry·2026
Same author

Effects of Sleep Duration on Electroencephalographic and Autonomic Nervous System Responses to High-Intensity Exercise.

Healthcare (Basel, Switzerland)·2026
Same author

Neural phase microscopy with metasurface optics for real-time and nanoscale quantitative phase imaging.

Nature communications·2026
Same author

Compact eye camera with two-third wavelength phase-delay metalens.

Nature communications·2025
Same author

Multi-objective optimization of dynamic VO<sub>2</sub> metagrating: broadband polarization-independent transmission modulator.

Optics express·2024

Related Experiment Video

Updated: May 3, 2026

High-resolution, High-speed, Three-dimensional Video Imaging with Digital Fringe Projection Techniques
11:34

High-resolution, High-speed, Three-dimensional Video Imaging with Digital Fringe Projection Techniques

Published on: December 3, 2013

16.3K

Depth-fused display with improved viewing characteristics.

Soon-Gi Park, Jae-Hyun Jung, Youngmo Jeong

    Optics Express
    |February 12, 2014
    PubMed
    Summary
    This summary is machine-generated.

    We introduce a hybrid depth-fused display (DFD) that improves viewing angles and depth range. This innovative 3D display technology enhances visual experiences without increasing system size.

    More Related Videos

    Soft Lithographic Procedure for Producing Plastic Microfluidic Devices with View-ports Transparent to Visible and Infrared Light
    10:26

    Soft Lithographic Procedure for Producing Plastic Microfluidic Devices with View-ports Transparent to Visible and Infrared Light

    Published on: August 17, 2017

    13.3K
    Troubleshooting FoCUS Image Acquisition: Patient Positioning, Transducer Manipulation, and Image Optimization
    06:50

    Troubleshooting FoCUS Image Acquisition: Patient Positioning, Transducer Manipulation, and Image Optimization

    Published on: March 3, 2023

    2.6K

    Related Experiment Videos

    Last Updated: May 3, 2026

    High-resolution, High-speed, Three-dimensional Video Imaging with Digital Fringe Projection Techniques
    11:34

    High-resolution, High-speed, Three-dimensional Video Imaging with Digital Fringe Projection Techniques

    Published on: December 3, 2013

    16.3K
    Soft Lithographic Procedure for Producing Plastic Microfluidic Devices with View-ports Transparent to Visible and Infrared Light
    10:26

    Soft Lithographic Procedure for Producing Plastic Microfluidic Devices with View-ports Transparent to Visible and Infrared Light

    Published on: August 17, 2017

    13.3K
    Troubleshooting FoCUS Image Acquisition: Patient Positioning, Transducer Manipulation, and Image Optimization
    06:50

    Troubleshooting FoCUS Image Acquisition: Patient Positioning, Transducer Manipulation, and Image Optimization

    Published on: March 3, 2023

    2.6K

    Area of Science:

    • Optics and Photonics
    • Display Technology
    • Computer Vision

    Background:

    • Conventional depth-fused displays (DFD) have limitations in viewing angle and expressible depth range.
    • Existing three-dimensional (3D) display methods like multi-view and integral imaging have their own strengths and weaknesses.

    Purpose of the Study:

    • To propose and demonstrate a novel depth-fused display (DFD) with enhanced viewing characteristics.
    • To extend the viewing angle and expressible depth range of DFDs by hybridization.
    • To achieve these improvements without increasing the physical volume of the display system.

    Main Methods:

    • Hybridizing depth-fusing technology with multi-view or integral imaging techniques.
    • Developing an experimental system to validate the proposed hybridization method.
    • Evaluating the enhanced viewing characteristics, including viewing angle and depth range.

    Main Results:

    • The hybridized DFD system demonstrated extended viewing angles compared to conventional DFDs.
    • The expressible depth range was significantly increased through the hybridization approach.
    • Experimental validation confirmed the feasibility and effectiveness of the proposed method.

    Conclusions:

    • Hybridizing depth-fusing technology with other 3D display methods offers a viable solution for enhanced viewing characteristics.
    • The proposed approach effectively expands the performance of DFDs without compromising system size.
    • This work paves the way for more immersive and versatile 3D display applications.