Related Experiment Video
Updated: May 3, 2026

Screening for Endocrine Activity in Water Using Commercially-available In Vitro Transactivation Bioassays
Published on: December 4, 2016
Key learnings from performance of the U.S. EPA Endocrine Disruptor Screening Program (EDSP) Tier 1 in vitro assays
Matthew J LeBaron1, Katie K Coady, John C O'Connor
1Toxicology & Environmental Research and Consulting, The Dow Chemical Company, Midland, Michigan.
Abstract:
Tier 1 of the U.S. EPA Endocrine Disruptor Screening Program comprises 11 studies: five in vitro assays, four in vivo mammalian assays, and two in vivo nonmammalian assays. The battery is designed to detect compounds with the potential to interact with the estrogen, androgen, or thyroid signaling pathways. This article examines the procedures, results, and data interpretation for the five Tier 1 in vitro assays: estrogen receptor (ER) and androgen receptor binding assays, an ER transactivation assay, an aromatase assay, and a steroidogenesis assay. Data are presented from two laboratories that have evaluated approximately 11 compounds in the Tier 1 in vitro assays. Generally, the ER and androgen receptor binding assays and the aromatase assay showed good specificity and reproducibility. As described in the guideline for the ER transactivation assay, a result is considered positive when the test compound induces a reporter gene signal that reaches 10% of the response seen with 1 nM 17β-estradiol (positive control). In the experience of these laboratories, this cutoff criterion may result in false-positive responses. For the steroidogenesis assay, there is variability in the basal and stimulated production of testosterone and estradiol by the H295R cells. This variability in responsiveness, coupled with potential cell stress at high concentrations of test compound, may make it difficult to discern whether hormone alterations are specific steroidogenesis alterations (i.e., endocrine active). Lastly, both laboratories had difficulty meeting some recommended performance criteria for each Tier 1 in vitro assay. Data with only minor deviations were deemed valid.
More Related Videos
09:49Use of a Battery of Chemical and Ecotoxicological Methods for the Assessment of the Efficacy of Wastewater Treatment Processes to Remove Estrogenic Potency
Published on: September 11, 2016
05:47In Silico Modeling Method for Computational Aquatic Toxicology of Endocrine Disruptors: A Software-Based Approach Using QSAR Toolbox
Published on: August 28, 2019