Related Experiment Video
Updated: May 3, 2026

Irradiator Commissioning and Dosimetry for Assessment of LQ α and β Parameters, Radiation Dosing Schema, and in vivo Dose Deposition
Published on: March 11, 2021
32P measurement and dose conversion factor evaluation of activated human hair by criticality accident
Seokwon Yoon1, Wi-Ho Ha2, Seyoung Park1
1National Radiation Emergency Medical Center, Korea Institute of Radiological and Medical Sciences, Seoul, Korea.
Abstract:
In order to conduct dose assessment of victims in criticality accidents, a method of fast neutron capture-activated (32)P measurement of hair in which samples are treated by a chemical and analytical procedure that takes 9 h and measurement is conducted by liquid scintillation counting is presented. To validate this measurement method, hair samples spiked with a (32)P reference source were measured and the results analysed and the optimal sample mass and detection efficiency were determined. To verify the correlation between (32)P-specific activity and absorbed dose for spectra with two neutron mean energies, samples collected from three normal individuals were irradiated at various neutron energies and irradiation times using the MC50 Cyclotron of the Korea Institute of Radiological and Medical Sciences. The (32)P-specific activity trend of the irradiated hair agreed well with the absorbed doses. Based on the results, dose conversion factors, which were 0.67 ± 0.15 and 0.59 ± 0.06 Gy (Bq g(-1))(-1) at neutron mean energies of 2.33 and 5.36 MeV, respectively, were calculated as a guide for medical treatment of criticality accident victims.