Potential risk of malposition of nasogastric tube using nose-ear-xiphoid measurement
Yen-Chun Chen1, Lien-Yen Wang2, Yu-Jun Chang3
1Department of Physical Medicine and Rehabilitation, Changhua Christian Hospital, Changhua, Taiwan.
Background:
Correct placement of nasogastric tubes provide proper functionality and maximize benefit and minimize risk. The Nose-Ear-Xiphoid (NEX) body surface estimate method is a long-lasting technique, and this study was conducted to evaluate the correlation between NEX method and the secure insertion depth of nasogastric tube.
Materials And Methods:
Thirty patients with nasogastric tube insertion who received whole body positron emission tomography with computerized tomography scan (PET-CT) were recruited. All data were gathered in the image center, which included Nose-Ear (NE), Ear-Xiphoid (EX), Nose-Ear-Xiphoid (NEX), glabella-xiphoid (GX) and glabella-umbilicus (GU) lengths. The distances of the inserted portion of the nasogastric tube between the cardiac and the nostril were measured by multiplanar reconstruction algorithm.
Results:
Only one patient successfully placed all side-holes into the stomach while using NEX method to estimate inserting depth. Twenty-nine patients (96.7%) failed to place correctly. Fourteen participants had one or more side-holes in both the esophagus and the stomach sides. Fifteen patients could not pass through any side-hole across the gastroesophageal junction. They had shorter EX distances (p = 0.02), but no difference among the NE distances. Body height had the highest statistical correlation with nasogastric tube length (adjusted R(2) = 0.459), as compared with the NEX, GX and GU body surface methods.
Conclusion:
This study suggests that NEX method is inappropriate for adult patients to estimate the ideal inserting length of nasogastric tube. Physicians should realize these underinsertions with any side-hole above the gastroesophageal junctions may increase the potential risk of complications.
Related Concept Videos
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Epistaxis
Etiology
Possible causes of this condition include high blood pressure, trauma, low humidity, upper respiratory tract infections, allergies, foreign bodies, nasal inhalation of corticosteroids or illicit drugs, excessive use of decongestant nasal sprays, facial or nasal surgery, anatomic malformation, tumors, or systemic...
Administering Oxygen by Nasal Cannula
Nasal Cannulas
A nasal cannula is a lightweight tube split into two prongs placed in the nostrils,...
Endotracheal Intubation I: Procedure
The ET tube comprises various components, including a standard adaptor to attach a bag-valve-mask (BVM) or ventilator, a cuff, a pilot balloon, and radiopaque markings along its length to measure the insertion distance. The tube sizes...
Enteral Nutrition I: Orogastric and Nasogastric Feeding
Orogastric (OG) and nasogastric (NG) feeding are two standard methods used for enteral nutrition. Enteral nutrition is often preferred over...
Enteral Nutrition II: Nasointestinal and Gastrostomy Feeding
Nasointestinal Feeding
Nasointestinal feeding involves placing a tube...