Chromatographic Fingerprinting by Template Matching for Data Collected by Comprehensive Two-Dimensional Gas Chromatography
Published on: September 2, 2020
Transfer of retention patterns in gas chromatography by means of response surface methodology
Milan Chhaganlal1, Liv K Skartland1, Svein A Mjøs2
1Department of Chemistry, University of Bergen, P.O. Box 7803, NO-5020 Bergen, Norway.
Abstract:
Accurate transfer of retention patterns in temperature-programmed gas chromatography is challenging because minor variations in column properties and experimental conditions may have significant impact on the elution patterns. An experimental method for accurate transfer of retention indices is proposed and validated. The methodology is based on response surface methodology and experimental design. The temperature rate and the start temperature of the rate are varied systematically in the region where the optimal conditions are expected to be found. Response surfaces that explain the absolute deviation to the target retention indices are calculated for each compound. These response surfaces are thereafter averaged and the minimum in the average surface is regarded as optimal conditions for reproduction of the retention pattern. The methodology was applied on fatty acid methyl esters using equivalent chain lengths as the retention index system. Two different target patterns were tested on two BPX-70 columns with different dimensions. Validation of the proposed conditions showed that the retention patterns could be reproduced with an error that was only fractions of a peak width.
More Related Videos
07:57Quantitative Detection of Trace Explosive Vapors by Programmed Temperature Desorption Gas Chromatography-Electron Capture Detector
Published on: July 25, 2014
05:31Gas Chromatography-Mass Spectrometry Paired with Total Vaporization Solid-Phase Microextraction as a Forensic Tool
Published on: May 25, 2021
Related Concept Videos
Response Surface Methodology
The process of RSM involves several key steps:
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...
Gas Chromatography: Sample Injection Systems
Two primary injection methods are used...
Silica Gel Column Chromatography: Overview
Polar components tend to bind strongly to the silica gel, causing them to move slowly through the column. In contrast, nonpolar compounds...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...