Related Experiment Video
Updated: May 3, 2026

Non-invasive Assessment of Microvascular and Endothelial Function
Published on: January 29, 2013
Effect of capillaroscopic patterns on the pulse oximetry measurements in systemic sclerosis patients
Ali Akdogan1, Levent Kilic1, Ismail Dogan1
1Hacettepe University Faculty of Medicine, Department of Internal Medicine, Division of Rheumatology, Ankara, Turkey.
Abstract:
Nailfold capillaroscopy is a simple method for determining microvascular damage in systemic sclerosis (SSc). The pulse oximeter is a noninvasive tool that is used to estimate a patient's arterial blood oxygen saturation. The aim of this study was to investigate the effect of capillaroscopic patterns on pulse oximetry measurements in SSc patients. The nailfolds from 2nd to 5th fingers in both hands were examined in all subjects by using capillaroscopy. Patients were categorized according to their capillaroscopy findings in 3 groups as having early, active or late patterns. Oxygen saturation (SpO2) measurements were performed from 2nd to 5th fingers in both hands with a finger probe. We studied 53 SSc patients (F/M: 48/5). According to capillaroscopy findings 18 patients were classified as having early pattern (34.0%), 19 active pattern (35.8%), and 15 late pattern (28.3%). Only 1 (1.9%) patient had normal capillaroscopy findings. SpO2 could not be measured in 47 (11.0%) fingers and in 20 (37.7%) SSc patients. There were 20 (37.7%) patients with a ≥4% difference between the minimum and maximum SpO2 measurements among fingers. There were no difference between the groups of SSc patients defined by capillaroscopy findings in terms of mean maximal SpO2 or mean minimal SpO2 measured from fingers (p NS, for all). Assessment of SpO2 values in patients with SSc is challenging. We did not detect any effect of capillaroscopic patterns on mean SpO2 values. On the other hand ≥4% difference between minimum and maximum SpO2 values measured from fingers of a patient may be considered as an indirect sign of microvascular damage. Assessment of the highest measured SpO2 values among the fingers of a patient may be more suitable in practice.
More Related Videos
14:28Non-Invasive Monitoring of Microvascular Oxygenation and Reactive Hyperemia using Hybrid, Near-Infrared Diffuse Optical Spectroscopy for Critical Care
Published on: May 10, 2024
07:18Evaluation of Capillary and Other Vessel Contribution to Macular Perfusion Density Measured with Optical Coherence Tomography Angiography
Published on: February 18, 2022
Related Concept Videos
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
Pulse
The pulse serves as a clinical...
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is...
Cardiovascular System Abnormal Findings I: Inspection and Palpation
Abnormal findings observed during an inspection
Special considerations while measuring pulse