Related Experiment Video
Updated: May 3, 2026

Single-Port Robotic-assisted Transaxillary Breast-conserving Surgery: A Prospective, Single-arm, Non-randomized Phase IIa Clinical Trial
Published on: August 19, 2025
[Radiation exposure of surgical staff during sentinel node surgery. Is there a risk for the surgeon and his team?]
M Bailly1, A Zinsius2, S Maia3
1Service de médecine nucléaire, hôpital Bretonneau, CHRU-hôpitaux de Tours, 2, boulevard Tonnelé, 37000 Tours, France.
Objective:
Assess the radiation exposure of surgical staff during sentinel node surgery in gynecology using a radiotracer, the (99m)Tc-microalbumin.
Materials And Methods:
A monocentric, prospective study was conducted during 3 months representing 40 sentinel node surgical procedures with different dosimetric measurements. Dosimeters were used to evaluate the whole body and the fingers radiation exposure for all exposed workers (surgeon, nurse and surgical assistant). Another dosimeter was used to estimate the atmospheric radiation level. The activity of (99m)Tc-microalbumin was 50.1±2.4MBq when the surgery was performed the same day and 90.4±3.2MBq when the surgery was performed the day after.
Results:
Radioactive doses received during each procedure by the surgeon, surgical assistant and nurse are 5, 3.75 and 0μSv for whole body exposure and 17.5, 15.6 and 16.2μSv for extremities respectively. Atmosphere dosimeter does not detect any radiation over this period. On average, 200 procedures are performed each year in our hospital by 7 surgeons. Surgeon's radiation exposure remains below the threshold of 1mSv annual for whole body and 50mSv annual for fingers set for public by the International Commission on Radiological Protection.
Discussion And Conclusions:
During sentinel node surgery radiation exposure of surgical staff is weak. Everyone, including the surgeon, receives a dose below the limits of the public radiation exposure. There is no need for special dosimetric monitoring or use radiation protective devices during the sentinel node surgery using (99m)Tc-microalbumin injection.