Related Experiment Video
Updated: May 2, 2026

Curtain Flow Column: Optimization of Efficiency and Sensitivity
Published on: June 12, 2016
In situ measurement of the transversal dispersion in ordered and disordered two-dimensional pillar beds for liquid
Selm De Bruyne1, Wim De Malsche, Sander Deridder
1Department of Chemical Engineering, Vrije Universiteit Brussel , Pleinlaan 2, 1050 Brussels, Belgium.
Abstract:
Using a fully transparent micropillar array chip and an optical "injection" setup capable of writing pulsed and continuous patterns into the flow by uncaging a fluorescent dye, highly detailed measurements of the transversal dispersion process in two-dimensional (2D) chromatographic beds could be made. With the use of water-glycerol mobile phase spanning a wide range of viscosities, the obtained data cover a broad range of reduced velocities (0 < ν < 3000) and show a clear leveling-off of the transversal dispersion coefficient at large reduced velocities. With dependence on the packing density, this leveling-off occurs at a value of about Dtrans/Dmol = 10 (ε = 0.4), Dtrans/Dmol = 4 (ε = 0.6) and Dtrans/Dmol = 2.5 (ε = 0.8). Another interesting observation that could be made is that the effect of the bed order on the observed transversal dispersion process is relatively small. The observed leveling-off in the relation between the measured Dtrans values and the reduced liquid velocity furthermore clearly invalidates the classical Galton-board model, predicting a linear increase of Dtrans with the reduced velocity. On the other hand, it corroborates a recently proposed series-connection transport model for Dtrans in 2D porous media.
Related Concept Videos
Diffusion on Chromatography Columns
Longitudinal diffusion occurs when the solute molecules in the mobile phase diffuse from the more concentrated center of the chromatographic band to the more dilute regions on either side, both towards and against the flow direction. This...
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
Column Efficiency: Rate Theory
During elution, a solute molecule experiences numerous transitions between stationary and mobile phases, exhibiting irregular residence times in...
Chromatographic Resolution
The effectiveness of separation can be evaluated by determining the level of separation between two neighboring peaks in a chromatogram, which represents the individual components of a sample.
In chromatography,...
High-Performance Liquid Chromatography: Elution Process
Principles Of Column Chromatography

